contactor configuration ac v oltage sensor E-312A-I 2pdt, 10 amps, 440 vac product specifications input voltage 440, 400 hz trip voltage 480 2% vac (3 average) at 25 c reset voltage 0 volts input time delay 5v above trip 0.5 to 1.5 second time delay at 500 vac .6 .15 second contacts 2pdt, hermetically sealed 10 amps resistive at 28 vdc 10 amps resistive at 115 vac 0.1 amp inductive at 115 vdc with transient of 0.75 amp for 60 m second temperature 0 c to 65 c weight 15 oz. features: ? 2pdt main contacts ? hermetically sealed ? three phase voltage sensor ? 440 vac, 400 hz, 3? operation ? 10 amps ? high reliability ? meets many requirements of mil-r-6106 notes: catalog ( we b d oc o nl y ) dimensions are in inches and dimensions are shown for usa: 1-800-522-6752 south america: 55-11-3611-1514 revised 5 -04 millimeters unless otherwise reference purposes only. canada: 1-905-470-4425 hong kong: 852-2735-1628 specified. values in brackets specifications subject mexico: 01-800-733-8926 japan: 81-44-844-8013 www.tycoelectronics.com are metric equivalents. to change. c. america: 52-55-5-729-0425 uk: 44-141-810-8967 har t ma n a er o spa ce po wer p ro duct s di men sion s fo r thi s pro du ct a re e xp re ss e d in in ch es . mu l ti pl y val ue s b y 25 .4 f or m ill im et er s . for factory-direct application assistance, con ta ct t h e ha rt ma n p rod uct te am at ( 41 9 ) 52 1 - 95 00 , fa x ( 41 9 ) 5 2 6 - 27 4 9 . ?200 4 by tyco electronics corporation. all rights reserved. ha rt ma n and tyco are trademarks.
|