Part Number Hot Search : 
LUG2040 2SB1731 B45192ER MA3200W 045CT FM107 400AC CY621
Product Description
Full Text Search
 

To Download AM30E-2403SZ Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  series am30e-z 30watt | dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.d 1 of 4 north america only features: ? wide 2:1 input range ? ? 1600 vdc i/o isolation ? ? adjustable output voltage ? ? soft start ? ? over current & over voltage protection ? ? over temperature protection models single output model input voltage (v) output voltage (v) output current max (a) maximum capacitive load (uf) efficiency (%) am30e-1203sz 9-18 3.3 8 20000 89 am30e-1205sz 9-18 5 6 14000 91 am30e-1205.1sz 9-18 5.1 6 14000 92 am30e-1212sz 9-18 12 2.5 2000 91 am30e-1215sz 9-18 15 2 2000 92 AM30E-2403SZ 18-36 3.3 8 20000 91 am30e-2405sz 18-36 5 6 14000 92 am30e-2405.1sz 18-36 5.1 6 14000 92 am30e-2412sz 18-36 12 2.5 2000 92 am30e-2415sz 18-36 15 2 2000 92 am30e-4803sz 36-75 3.3 8 20000 90 am30e-4805sz 36-75 5 6 14000 91 am30e-4805.1sz 36-75 5.1 6 14000 91 am30e-4812sz 36-75 12 2.5 2000 91 am30e-4815sz 36-75 15 2 2000 91 models dual output model input voltage (v) output voltage (v) output current max (ma) maximum capacitive load (uf) efficiency (%) am30e-1205dz 9-18 5 3 3000 89 am30e-1212dz 9-18 12 1.25 1300 90 am30e-1215dz 9-18 15 1 1300 91 am30e-2405dz 18-36 5 3 3000 90 am30e-2412dz 18-36 12 1.25 1300 91 am30e-2415dz 18-36 15 1 1300 91 am30e-4805dz 36-75 5 3 3000 90 am30e-4812dz 36-75 12 1.25 1300 90 am30e-4815dz 36-75 15 1 1300 90 note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. input specifications parameters nominal typical maximum units voltage range 12 9-18 vdc 24 18-36 48 36-75 filter (pi) network start up time 30 ms absolute ma ximum rating 12 -0.7 ~ 25 vdc 24 -0.7 ~ 50 48 -0.7 ~ 100 peak input voltage time 100 ms on/off control on: 3 ~12vdc or open circuit ; off - 0 ~ 1.2vdc or short circuit between pin 2 and pin 3
series am30e-z 30watt | dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.d 2 of 4 north america only input specifications (continued) parameters nominal typical maximum units under voltage lockout 12v on/off 8.6 / 7.9 vdc 24v on/off 17.8 / 16 48v on/off 33.5 / 30.5 isolation specifications parameters conditions typical rated units tested i/o voltage 3 sec 1600 vdc case/input tested voltage 3 sec 1600 vdc resistance 1000 mohm capacitance 1500 pf output specifications parameters conditions typical maximum units voltage accuracy 1 % cross regulation (dual output models) 25% load on one output 100% load on second load 5 % over voltage protection zener diode clamp over current protection 150 % short circuit protection continuous short circuit restart auto-recovery thermal shutdown on case 115 oc line voltage regulation hl-ll 0.5 % load voltage regulation (single) 0 ? 100% load 0.5 % load voltage regulation (dual) 0 ? 100% load 1 % temperature coefficient 0.02 %/ o c ripple & noise 20mhz bandwidth 100 mv p-p voltage adjustment range (single) 10 % minimum load current 0 % of max general specifications parameters conditions typical maximum units switching frequency 100% load 330 khz operating temperature derating above 50 -40 to +75 o c storage temperature -40 to +125 o c maximum case temperature 105 o c derating 2 %/ o c cooling free air convection humidity 95 % rh case material nickel coated copper weight 31 g dimensions (l x w x h) 2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.16 mm mtbf >435,000 hrs (mil-hdbk -217f, ground benign, t=+25oc)hours maximum soldering temperature 1.5mm from case for 10 sec 260 o c transient recovery time 250 ms transient recovery deviation 3 %
series am30e-z 30watt | dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.d 3 of 4 north america only safety specifications parameters agency approvals ce standards en55022 class a iec61000-4-2, perf. criteria b iec61000-4-3, perf. criteria a iec61000-4-4, perf. criteria a (e xternal 220uf/100v cap required) iec61000-4-5, perf. criteria a (e xternal 220uf/100v cap required) iec61000-4-6, perf. criteria a iec61000-4-8, perf. criteria a note: also designed to meet iec/en 60950-1 pin out specifications pin single dual 1 + v input + v input 2 - v input - v input 3 on/off control on/off control 4 + v output + v output 5 -v output common 6 trim - v output dimensions 1 2 3 2.54 (0.10) 5.08 (0.20) 10.16 (0.40) 50.80 (2.00) 25.40 (1.00) bottom view 2.54 (0.10) 2.54 (0.10) 10.16 (0.40) 10.16 (0.40) 10.16 (0.40) 5.08 (0.20) single and dual output models 5.08 (0.20) 4 5 6 notes: all dimensions are typical in millimeters (inches). pin pitch tolerance 0.35 (0.014) case tolerance 0.50 (0.02) diameter 1.00 (0.04)
series am30e-z 30watt | dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.d 4 of 4 north america only trimming derating control on/off positive logic turns on the module during high logic and off during low logic. module can be controlled by an external switch between the on /off ctrl terminal and ?vinput terminal. the switch can be either open collector or open drain recommended circuits c1 l c2 100uf, 100v 12uh 1206, 470pf, 2kv note: 1. datasheets are updated as needed and as such, specifications ar e subject to change without notic e. once printed or downloaded , datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency cert ifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an am bient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary an d may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control sys tems or other such applications which necessitate specific safety and regulatory standards ot her the ones listed in this datasheet. 7. warranty is in accordance with aimtec?s st andard terms of sale available at www.aimtec.com. -40 -20 0204060 80 100 100 80 60 40 20 0 safe operating area output power (%) 75 ambient temperature o c free air convection 50 o c conducted/radiated emissions single output l c1 c2 dc/dc converter +v input -v input +v output load -v output conducted/radiated emissions dual output l c1 c2 dc/dc converter +v input -v input +v output common load load -v output


▲Up To Search▲   

 
Price & Availability of AM30E-2403SZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X