Part Number Hot Search : 
SD550T CSNR151 DP308 SR106 500MA P6KE150 PL002 PCBB21T
Product Description
Full Text Search
 

To Download FMER-G62P-2517 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products dc filter for photovoltaic converters description - compact dc filter for photovoltaic systems - high symmetrical and asymmetrical attenuation - in the frequency range from 150khz up to 300mhz standards - iec 60939 - ul 1283, edition 5, csa 22.2 no. 8-m1986, @ ta 55 (75) c approvals - ul file number: e72928 applications - voltage up to 1200 vdc for world wide acceptance - ul approved 1000vdc, 250 - 2300a and 600vdc, 25 - 150a - helps to meet international emc standards weblinks pdf-datasheet, html-datasheet, general product information, approvals , ce declaration of conformity , rohs, china-rohs, e-shop, schurter-stock-check , distributor-stock-check, detailed request for product technical data rated current 25 - 2300 (1200) a @ ta 55 (75) c rated voltage 1200 vdc max. approval for 25 - 2300 a @ ta 55 c / 1200 vdc overload current 1.5 x ir number of filter stages 1-stage weight 1 - 32 kg material: housing metal sealing compound ul 94v-0 mounting screw-on mounting on chassis, from top terminal screw clamps for types up to 150 a and copper bars for types upwards of 250 a. operating temperature [c] -40 c to 100 c climatic category 40/100/21 acc. to iec 60068-1 degree of protection ip 20 (25a-150a types), ip 00 (250a-2300a types) acc. to iec 60529 protection class suitable for appliances with protection class i acc. to iec 61140
2 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products dimensions case 2p 20 40 max. 175 140 170 max. 80 20 23 13 m5x13; 2-2.5 nm 40 40 max. 65 0 ?2 150 1) 2) 5.4 (6x) 0.3 10mm 2 ; 1.5-1.8nm 60 0.3 45 0.3 1) pv module 2) inverter case 2q 50 m6x14; 3-4 nm 1) 2) 5.4 (4x) 0.3 25mm 2 ; 2-2.2 nm max. 210 170 max. 95 30 20 15 0 ?2 180 200 max. 80 45 75 0.3 60 0.3 45 15 1) pv module 2) inverter
3 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products case 2r 55 m8x25; 6-10 nm 1) 2) 5.4 (6x) 0.3 50mm 2 ; 6- 8 nm max. 275 190 30 max. 125 35 35 16 0 ?2 200 220 max. 95 60 100 0.3 80 0.3 60 1) pv module 2) inverter case 2s 55 m10x30; 10-17 nm 1) 2) 5.4 (6x) 0.3 95mm 2 ; 15-20 nm 25 max. 140 40 45 15 0 ?2 230 250 220 max. 320 max. 115 60 120 0.3 100 0.3 60 1) pv module 2) inverter
4 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products case 2t m10x30; 10-17 nm 1) 2) 50 90 40 2 90 15 max. 300 1 15 1 70 2 max. 415 ? 9 (4x) 0.3 50 max. 130 20 max. 110 5 240 1 110 1 155 1 max. 180 ? 12.5 (6x) 0.3 1) pv module 2) inverter case 2u1 m10x30; 10-17 nm 1) 2) 25 90 40 2 90 15 max. 300 1 15 1 70 2 max. 415 ? 10.5 (4x) 0.3 25 max. 140 25 max. 110 240 1 110 1 165 1 max. 190 ? 12.5 (6x) 0.3 6 1) pv module 2) inverter
5 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products case 2u2 m10x30; 10-17 nm 1) 2) 25 90 40 2 90 15 max. 300 1 15 1 70 2 max. 415 ? 10.5 (4x) 0.3 25 max. 140 25 max. 110 240 1 110 1 165 1 max. 190 ? 12.5 (6x) 0.3 8 1) pv module 2) inverter case 2v m12x25; 14-30 nm 1) 2) 65 115 65 2 115 max. 300 20 1 20 1 70 2 max. 430 ? 14 (4x) 0.3 65 max. 150 40 max. 140 240 1 110 1 175 1 max. 200 ? 12.5 (6x) 0.3 8 1) pv module 2) inverter
6 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products case 2w m12x25; 14-30 nm 1) 2) 65 125 60 2 125 max. 300 17 1 43 1 17 1 70 2 43 1 max. 500 ? 14 (8x) 0.3 65 60 max. 150 240 1 110 1 175 1 max. 200 ? 12.5 (6x) 0.3 10 26 1 max. 150 1) pv module 2) inverter case 2z m16x40; 60-80 nm 35 72 100 400 100 100 2 max. 600 ? 14 (16x) 0.3 max. 195 70 38 max. 180 15 225 1 max. 250 ? 12 (6x) 0.3 (190) 150 1 340 1 (2x) (2x) 35 20 35 20 0.2 1) 2) 35 1) pv module 2) inverter
7 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products diagrams standard version pe pe 1) 2) 1) photovoltaic module 2) frequency inverter version with low leakage current pe pe 1) 2) 1) photovoltaic module 2) frequency inverter 1 a 2 3 4 1) photovoltaic module 2) dc filter 3) frequency inverter 4) ac filter a) power grid derating curves permissible working current as a function of ambient temperature admissible operating current in % of in 0 20 40 55 75 100 100 80 60 40 20 0 ul listed ambient air temperature ta c
8 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products attenuation loss . . . . . 0.1/100? differential mode ........... 100/0.1? differential mode - - - - differential mode _____ common mode standard version 25 a 50 a 75 a 100 a 150 a 250 a 400 a 600 a 800 a 1000 a 1500 a 2300 a low leakage current version 25 a 50 a 75 a 100 a 150 a 250 a 400 a 600 a 800 a 1000 a 1500 a 2300 a
9 3-phase ac filters / dc filters fmer sol www.schurter.com/pg80 emc products variants rated current @ ta 55c (75c) [a] rated voltage [vdc] curus approval [vdc] power loss [w] weight [kg] housing order number 25 (19) 1200 600 4,1 1 kg 2p fmer-g92p-2517 50 (37) 1200 600 11,5 2 kg 2q fmer-g92q-5017 75 (56) 1200 600 11,3 2 kg 2q fmer-g92q-7517 100 (75) 1200 600 12,6 3 kg 2r fmer-g92r-j017 150 (112) 1200 600 17,6 5 kg 2s fmer-g92s-j517 250 (186) 1200 1000 7,8 8 kg 2t fmer-g92t-k557 400 (298) 1200 1000 13,3 9 kg 2u1 fmer-g92u-m057 600 (447) 1200 1000 22,4 10 kg 2u2 fmer-g92u-u057 800 (596) 1200 1000 24,8 13 kg 2v fmer-g92v-q057 1000 (745) 1200 1000 38,8 13 kg 2v fmer-g92v-s057 1500 (1118) 1200 1000 45,0 32 kg 2w fmer-g92w-s557 2300 (1200) 1200 1000 80,5 32 kg 2z fmer-g92z-t357 25 (19) 1200 600 4,1 1 kg 2p FMER-G62P-2517 50 (37) 1200 600 11,5 2 kg 2q fmer-g62q-5017 75 (56) 1200 600 11,3 2 kg 2q fmer-g62q-7517 100 (75) 1200 600 12,6 3 kg 2r fmer-g62r-j017 150 (112) 1200 600 17,6 5 kg 2s fmer-g62s-j517 250 (186) 1200 1000 7,8 8 kg 2t fmer-g62t-k557 400 (298) 1200 1000 13,3 9 kg 2u1 fmer-g62u-m057 600 (447) 1200 1000 22,4 10 kg 2u2 fmer-g62u-u057 800 (596) 1200 1000 24,8 13 kg 2v fmer-g62v-q057 1000 (745) 1200 1000 38,8 13 kg 2v fmer-g62v-s057 1500 (1118) 1200 1000 45,0 32 kg 2w fmer-g62w-s557 2300 (1200) 1200 1000 80,5 32 kg 2z fmer-g62z-t357 fmer-g62x-xxxx: low leakage current version without capacitor to ground the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments. 13.05.2013


▲Up To Search▲   

 