signal conditioned pressure sensors 0 -1 psi to 0 - 150 psi ascx series features calibrated & temperature compensated 4.5 volt span ? v olt supply small size absolute & differential (gauge) pressures reliable semiconductor t echnology typical applications industrial controls medical equipment pneumatic controls electrical connection this series is an amplified version of sensym s proven performer and industry leading scx series sensor. this amplified ascx device is in a package with the same footprint as the scx but it offers a high level (4.5 v span) output on a very cost effective basis. this family is fully calibrated and temperature compensated. these sensors are intended for use with non-corrosive, non-ionic working fluids; such as air and dry gases. devices are available to measure absolute differential and gauge pressures from 1 psi (ascx01dn) through 150 psi (ascx150dn). the absolute devices have an internal vacuum reference and an output voltage proportional to absolute pressure. differential devices allow application of pressure to either side of the sensing diaphragm and can be used for gauge or differential measurements. all ascx devices are calibrated for span to within +/- 1%. the devices are characterized for operation from a single 5 volt supply although sensitivity is ratiometric to the supply voltage and any dc supply from 5 to 16 volts is acceptable. contact your local sensym ict representative, the factory, or go to sensym ict s web site at www.sensym-ict.com for additional details. automation and control products ? honeywell 2002, all rights reserved 12 3 4 56 pin 1: external offset adjust pin 2: vs pin 3: + output pin 4: ground pin 5: n/c pin 6: n/c w arning personal injury do not use these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. failure to comply with these instructions could result in death or serious injury. w arning misuse of documentation ?the information presented in this product sheet is for reference only. do not use this document as a product installation guide. ?complete installation, operation, and maintenance information is provided in the instructions supplied with each product. failure to comply with these instructions could result in death or serious injury. ! !
ascx series 2 honeywell ?automation and control products signal conditioned pressure sensors 0 -1 psi to 0 - 150 psi pressure sensor characteristics (all devices) maximum ratings supply voltage v s = 4.5 to 15 vdc maximum pressure on any port 150 psi output current lead temperature (2-4 sec.) 250? source 5 ma sink 3 ma quiescent current 4 ma environmental specifications te mperature range insulation resistance (min.) 100 mw at 50 vdc compensated 0? to 70? vibration 10 g at 20-2000 hz operating -25? to 105? shock 100 g for 11 mscc storage -55? to 125? life 1 million cycles minimum pressure range specifications sensym part no. pressure range proof pressure (6) sensitivity ascx01dn 0-1 psid 20 psig 4.5 v/psi ascx05dn 0-5 psid 20 psig 0.9 v/psi ascx15an 0-15 psia 30 psig 0.3 v/psi ascx15dn 0-15 psid 30 psig 0.3 v/psi ascx30an 0-30 psia 60 psia 0.15 v/psi ASCX30DN 0-30 psid 60 psid 0.15 v/psi ascx100an 0-100 psia 150 psia 0.045 v/psi ascx100dn 0-100 psid 150 psid 0.045 v/psi ascx150an 0-150 psia 150 psia 0.030 v/psi ascx150dn 0-150 psid 150 psid 0.030 v/psi specification notes note 1: reference conditions (unless otherwise noted): t a = 25?, supply voltage v s = 5 vdc. note 2: full-scale span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. full-scale span is ratiometric to the supply voltage. note 3: pressure non-linearity is based on best-fit straight line. pressure hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. note 4: maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25? reading. note 5: response time for 0 psi to full-scale pressure step change. note 6: if maximum pressure is exceeded, even momentarily, the package may leak or burst, or the pressure-sensing die may fracture. ascx performance characteristics (1) ascx15/30/100/150 ascx01/05 characteristic min typ max min typ max units zero pressure offset 0.205 0.250 0.295 0.180 0.250 0.320 v full-scale span (2) 4.455 4.500 4.545 4.430 4.500 4.570 v output at fs pressure 4.660 4.750 4.840 4.610 4.750 4.890 v combined pressure non-linearity and pressure hysteresis (3) 0.1 0.5 0.1 0.5 %fss te mperature effect on span (4) 0.2 1.0 0.2 1.5 %fss te mperature effect on offset (4) 0.2 1.0 0.2 1.5 %fss response time (10% - 90%) (5) 0.1 0.1 ms repeatability 0.05 0.05 %fss
sensing and control honeywell 11 w est spring street freeport, illinois 61032 pk xxxxx-x-xx il50 glo myr printed in usa www.honeywell.com/sensing w arranty/remedy honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. contact your local sales office for warranty information. if warranted goods are returned to honeywell during the period of coverage, honeywell will repair or replace without charge those items it finds defective. the foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. specifications may change without notice. the information we supply is believed to be accurate and reliable as of this printing. however, we assume no responsibility for its use. while we provide application assistance personally, through our literature and the honeywell web site, it is up to the customer to determine the suitability of the product in the application. for application assistance, current specifications, or name of the nearest authorized distributor, contact a nearby sales office. or call: 1-800-537-6945 usa 1-800-737-3360 canada 1-815-235-6847 international fax 1-815-235-6545 usa internet www.honeywell.com/sensing info.sc@honeywell.com ascx series signal conditioned pressure sensors 0 -1 psi to 0 - 150 psi 2 14 36 5 1.10 [27.9] mounting holes ?.14 [?3.6] thru rivet .85 [21.6] .80 [20.3] 1.03 [26.2] ref. .05 [1.3] .55 [14.0] .36 [9.1] .48 [12.2] .06 [1.5] b ?.08 [?2.0] i.d. hole pressure port .13 [3.3] .42 [10.7] 1 .08 [27.4] .41 [10.7] .25 [6.4] ?.19 [4.8] 2 pls .10 [2.5] typ .05 [1.3] a physical dimensions dimensions in inches [mm]
|