  scotchlok terminals m18-4fl thru m10-14fl locking fork, non-insulated, brazed seam data sheet specifications wire size: see table above barrel seam: brazed max. current: same as wire terminal material: etp copper plating: tin installation information ul listed and csa certified for use on stranded copper (awg) wire only. strip away the end 3/8 inch of wire insulation. make the crimp in the proper station of a recommended 3m crimp tool: th-440, th-450 (scissor style), or tr-490 (ratchet style) hand tools. barrel crimp (required) w l e c listed 314r underwriters laboratories standard no. ul 486a 3m file no. e23438 t c u d o r p r e b m u n e r i w e g n a r ) g w a ( d u t s e z i s x a m k c o l h t d i wwcle s s e n k c i h t l e r r a b h t g n e l l e r r a b . d . i l f 4 - 8 1 m8 1 - 2 247 2 . 05 2 . 05 2 . 08 6 . 00 5 . 00 3 0 . 05 2 . 00 7 0 . 0 l f 6 - 8 1 m8 1 - 2 267 2 . 05 2 . 05 2 . 08 6 . 00 5 . 00 3 0 . 05 2 . 00 7 0 . 0 l f 8 - 8 1 m8 1 - 2 284 3 . 00 3 . 05 2 . 08 6 . 00 5 . 00 3 0 . 05 2 . 00 7 0 . 0 l f 0 1 - 8 1 m8 1 - 2 20 1 5 3 . 0 2 3 . 05 2 . 08 6 . 00 5 . 00 3 0 . 05 2 . 00 7 0 . 0 l f 4 - 4 1 m4 1 - 6 147 2 . 05 2 . 05 2 . 08 6 . 00 5 . 00 3 0 . 05 2 . 00 9 0 . 0 l f 6 - 4 1 m4 1 - 6 167 2 . 05 2 . 05 2 . 08 6 . 00 5 . 00 3 0 . 05 2 . 00 9 0 . 0 l f 8 - 4 1 m4 1 - 6 184 3 . 00 3 . 05 2 . 08 6 . 00 5 . 00 3 0 . 05 2 . 00 9 0 . 0 l f 0 1 - 4 1 m4 1 - 6 10 15 3 . 02 3 . 05 2 . 08 6 . 00 5 . 00 3 0 . 05 2 . 00 9 0 . 0 l f 4 1 - 4 1 m4 1 - 6 14 / 18 4 . 03 4 . 00 4 . 00 9 . 05 6 . 00 3 0 . 05 2 . 00 9 0 . 0 l f 6 - 0 1 m0 1 - 2 160 3 . 08 2 . 08 2 . 03 7 . 03 5 . 00 4 0 . 05 2 . 05 3 1 . 0 l f 8 - 0 1 m0 1 - 2 185 3 . 02 3 . 08 2 . 03 7 . 03 5 . 00 4 0 . 05 2 . 05 3 1 . 0 l f 0 1 - 0 1 m0 1 - 2 10 16 3 . 02 3 . 08 2 . 03 7 . 03 5 . 00 4 0 . 05 2 . 05 3 1 . 0 l f 4 1 - 0 1 m0 1 - 2 14 / 18 4 . 03 4 . 04 4 . 04 9 . 09 6 . 00 4 0 . 05 2 . 05 3 1 . 0 warning turn power off before installing or removing terminal. all electrical work should be done according to appropriate electrical codes. canadian standards association standard no. c22.2 no. 0. 65 3m file no. lr22190
electrical products division 6801 river place blvd. austin, tx 78726-9000 http://www.3m.com/elpd litho in usa. 3m 2002 78-8126-0485-4-a important notice before using this product, you must evaluate it and determine if it is suitable for your intended application. you assume all ri sks and liability associated with such use. warranty; limited remedy; limited liability. this product will be free from defects in material and manufacture as of the date of purchase. 3m makes no other warranties including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose. if this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3ms option, to replace or repair the 3m product or refund the purchase price of the 3m product. except where prohibited by law, 3m will not be liable for any loss or damage arising from this 3m product, whether direct, indirect, special, incidental or consequent ial regardless of the legal theory asserted. 3m and scotchlok are trademarks of 3m engineering specification crimp-type terminals shall, electrically and mechanically, connect to a pre-stripped end of a stranded copper wire: and have a flat tongue portion with a central opening for mounting around a screw or stud. the terminal line shall offer tongue variations in hole (stud) size (6, 8 10, etc.) and configuration (ring, fork, block fork, flanged block fork, locking fork, etc.): and barrel variations in wire (awg) size (22-18, 16-14, 12-10, etc.) and construction (non-insulated brazed seam, vinyl insulated butted seam, nylon insulated with insulation grip, etc.). the terminal line shall have regulatory agency coverage (ul listing, csa certification). the terminal tongue shall be marked with the wire range and manufacturer s symbol ( ). the non-insulated, brazed seam locking fork terminal shall be tin-plated, annealed copper, with the tongue having a specified stud slot (size 4 thru 1/4 in.) and a brazed seam barrel with a beveled i.d. for ease of stranded wire entry, sized for a specified (awg) wire range (22-18, 16-14, 12-10). non-insulated terminals shall be ul listed and csa certified.


▲Up To Search▲   

 
Price & Availability of 3MELECTRONICPRODUCTSDIVISION-M14-10FL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X