general purpose fuses general purpose fuses 29 www.littelfuse.com ? 2005 littelfuse ? powr-gard ? products catalog littelfuse flnr_id/flsr_id indicator fuses provide blown fuse indication at a glance. the patented state-of-the-art solid state design provides maximum reliability and superior performance characteristics in a true dual-element design. the use of indicator fuses reduces downtime and nuisance openings, increases safety, and can save thousands of dollars in lost production time. applications service entrance switches switchboard main and feeder switches motor control center mains and motor branch circuits individual fused combination motor controllers distribution panelboards industrial control panels protection of fully rated panelboards and loadcenters all general purpose circuits features/benefits ? reduce downtime a glance at the indicating window of a flnr_id or flsr_id indicator fuse pinpoints open fuses. if the indicating strip is black, the fuse has opened. its that simple. ? reduce nuisance opening flnr_id and flsr_id indicator fuses have superior time-delay and cycling characteristics which can lengthen fuse life and decrease needless opening. ? reduce fuse inventory because flnr_id and flsr_id indicator fuses have superior performance characteristics, they can be used on a variety of ap pli ca tions, thus decreasing fuse inventory. ? reduce equipment damage flnr_id and flsr_id indicator fuses have superior overload and short-circuit protection which can reduce equipment damage. ? reduce accidents the flnr_id and flsr_id indicator fuses improve safety by minimizing exposure to live circuits. unlike other forms of blown fuse indication, it doesnt matter if the power is on or off. no second guessing whether a light means a fuse is good or bad, and no current going across a blown fuse to power a lighted accessory. flnr_id/flsr_id indicator ? class rk5 fuses 250/600 vac ? dual-element, time delay ? 1/10 C 600 amperes specifications voltage ratings: ac: 250 volts (flnr_id); 600 volts (flsr_id) dc: 125 volts (flnr 1 ? 10 C 30a); 125 volts (flnr_id 35 C 600a); 300 volts (flsr_id) interrupting ratings: ac: 200,000 amperes rms symmetrical 300,000 amperes rms sym met ri cal (littelfuse self-certified) dc: 20,000 amperes ampere range: 1 ? 10 C 600 amperes approvals: standard 248-12, class rk5 ul listed (file no: e81895) csa certified (file no: lr29862) qpl: federal specification wf-1814 ampere ratings 1 ? 10 ** 6 ? 10 1 8 ? 10 4 8 30 80 225 1 ? 8 8 ? 10 2 4 1 ? 2 9 35 90 250 15 ? 100 1 2 1 ? 4 5 10 40 100 300 2 ? 10 1 1 ? 8 2 1 ? 2 5 6 ? 10 12 45 110 350 1 ? 4 1 1 ? 4 2 8 ? 10 6 15 50 125 400 3 ? 10 1 4 ? 10 3 6 1 ? 4 17 1 ? 2 60 150 450 4 ? 10 1 1 ? 2 3 2 ? 10 7 20 70 175 500 1 ? 2 1 6 ? 10 3 1 ? 2 7 1 ? 2 25 75* 200 600 *flsr_id only **flnr only ex am ple part number (series & am per age): flsr100id note: for 1 ? 10 C 30 ampere 250 volt fuses, order non-indicating flnr series fuses. note: all flnr_id fuses rated 35 C 600a are indicator fuses. note: all flsr_id fuses rated 1 amp and above are indicator fuses. recommended fuse blocks lr250 series (for flnr_id series fuses) lr600 series (for flsr_id series fuses) refer to blocks & holders section of this catalog for ad di tion al in for ma tion.
general purpose fuses general purpose fuses 30 www.littelfuse.com ? 2005 littelfuse ? powr-gard ? products catalog flnr_id/flsr_id indicator ? class rk5 fuses 250/600 vac ? dual-element, time delay ? 1/10 C 600 amperes time in seconds current in amperes flsr_i d .01 .02 .03 .04 .06 .08 .1 .2 .3 .4 .6 .8 1 2 3 4 6 8 10 20 30 40 60 80 100 200 300 400 600 800 1000 10 8 6 4 3 2 1 10000 8000 6000 4000 3000 2000 1000 800 600 400 300 200 100 80 60 40 30 20 1a 1.25a 1.6a 2a 2.5a 3a 4a 6a 10a 15a 20a 25a 30a 1000 800 600 400 300 200 100 80 60 40 30 20 10 8 6 4 3 2 1 .8 .6 .4 .3 .2 .1 .08 .06 .04 .03 .02 .01 2 3 4 6 8 10 20 30 40 60 80 100 200 300 400 600 800 1000 .1 .2 .3 .4 .6 .8 1 2/10a 1/4a 3/10a 4/10a 1/2a 6/10a 8/10a 1a 1 1/4a 1 4/10a 2a 2 1/2a 4 1/2a 5a 7a 7 1/2a 9a flnr time in seconds current in amperes a f e c d g b a j k h b c f dg 70-600a fig. 1 fig. 2 e amperes refer to fig. no. series dimensions in inches (mm in parentheses) a b c d e f g h j k 1 / 10 C 30 1 flnr 2 (50.8) 1 ? 2 (12.7) 1 ? 2 (12.7) 9 ? 16 (14.3) 5 ? 64 (2.0) 5 ? 32 (4.0) 3 ? 8 (9.5) flsr_id 5 (127.0) 3 ? 4 (19.1) 5 ? 8 (15.9) 13 ? 16 (20.6) 3 ? 32 (2.4) 3 ? 16 (4.8) 5 ? 8 (15.9) 35 C 60 1 flnr_id 3 (76.2) 3 ? 4 (19.1) 5 ? 8 (15.9) 13 ? 16 (20.6) 3 ? 32 (2.4) 3 ? 16 (4.8) 5 ? 8 (15.9) flsr_id 5 1 ? 2 (139.7) 1 (25.4) 5 ? 8 (15.9) 1 1 ? 16 (27.0) 3 ? 32 (2.4) 1 ? 4 (6.4) 7 ? 8 (22.2) 70 C 100 2 flnr_id 5 7 ? 8 (149.2) 1 (25.4) 1 1 ? 16 (27.0) 1 1 ? 16 (27.0) 1 ? 8 (3.2) 3 ? 4 (19.1) 1 1 ? 4 (31.8) 1 ? 4 (6.4) 9 ? 32 (7.1) 1 ? 2 (12.7) flsr_id 7 7 ? 8 (200.0) 1 1 ? 4 (31.8) 1 1 ? 16 (27.0) 1 5 ? 16 (33.3) 1 ? 8 (3.2) 3 ? 4 (19.1) 1 1 ? 2 (38.1) 1 ? 4 (6.4) 9 ? 32 (7.1) 1 ? 2 (12.7) 110 C 200 2 flnr_id 7 1 ? 8 (181.0) 1 1 ? 2 (38.1) 1 15 ? 32 (37.3) 1 19 ? 32 (40.5) 3 ? 16 (4.8) 1 1 ? 8 (28.6) 1 27 ? 32 (46.8) 7 ? 16 (11.1) 9 ? 32 (7.1) 11 ? 16 (17.5) flsr_id 9 5 ? 8 (244.5) 1 3 ? 4 (44.5) 1 15 ? 32 (37.3) 1 27 ? 32 (46.8) 3 ? 16 (4.8) 1 1 ? 8 (28.6) 2 3 ? 32 (53.2) 7 ? 16 (11.1) 9 ? 32 (7.1) 11 ? 16 (17.5) 225 C 400 2 flnr_id 8 5 ? 8 (219.1) 2 (50.8) 1 15 ? 16 (49.2) 2 3 ? 32 (53.2) 1 ? 4 (6.4) 1 5 ? 8 (41.3) 2 11 ? 32 (59.5) 5 ? 8 (15.9) 13 ? 32 (10.3) 15 ? 16 (23.8) flsr_id 11 5 ? 8 (295.3) 2 1 ? 2 (63.5) 2 (50.8) 2 19 ? 32 (65.9) 1 ? 4 (6.4) 1 5 ? 8 (41.3) 2 27 ? 32 (72.2) 5 ? 8 (15.9) 13 ? 32 (10.3) 15 ? 16 (23.8) 450 C 600 2 flnr_id 10 3 ? 8 (263.5) 2 1 ? 2 (63.5) 2 3 ? 8 (60.3) 2 19 ? 32 (65.9) 1 ? 4 (6.4) 2 (50.8) 2 27 ? 32 (72.2) 3 ? 4 (19.1) 17 ? 32 (13.5) 1 1 ? 8 (28.6) flsr_id 13 3 ? 8 (339.7) 3 (76.2) 2 13 ? 32 (61.1) 3 3 ? 32 (78.6) 1 ? 4 (6.4) 2 (50.8) 3 11 ? 32 (84.9) 3 ? 4 (19.1) 17 ? 32 (13.5) 1 1 ? 8 (28.6) for additional application information request product bulletin el-4
general purpose fuses general purpose fuses 31 www.littelfuse.com ? 2005 littelfuse ? powr-gard ? products catalog current-limiting effects of flnr_id (250v) fuses short-circuit current* apparent rms symmetrical current for various fuse ratings 30a 60a 100a 200a 400a 600a 5,000 1,400 2,100 3,100 5,000 5,000 5,000 10,000 1,550 2,500 3,900 6,500 9,500 10,000 15,000 2,000 3,150 4,400 7, 25 0 10,500 14,000 20,000 2,250 3,400 5,000 8,250 12,000 16,000 25,000 2,400 3,750 5,250 9,000 12,500 16,500 30,000 2,550 4,100 5,600 9,500 13,500 18,000 35,000 2,650 4,300 5,800 9,750 14,000 19,000 40,000 2,800 4,400 6,250 10,250 15,000 20,000 50,000 3,000 5,000 6,500 10,500 16,000 21,000 60,000 3,200 5,250 7,000 11,500 17,000 23,000 80,000 3,400 5,750 7,500 12,500 19,000 25,500 100,000 3,850 6,000 8,000 13,500 21,000 27,500 150,000 4,100 7,000 9,000 15,200 24,000 31,500 200,000 4,300 7,500 9,750 16,500 26,000 34,000 * prospective rms symmetrical amperes short-circuit current note: data derived from peak let-thru curves current-limiting effects of flsr_id (600v) fuses short-circuit current* apparent rms symmetrical current for various fuse ratings 30a 60a 100a 200a 400a 600a 5,000 1,250 2,100 3,200 5,000 5,000 5,000 10,000 1,600 2,850 4,300 7, 25 0 10,000 10,000 15,000 1,800 3,400 5,000 8,500 13,500 15,000 20,000 2,250 3,800 5,500 9,500 15,750 19,000 25,000 2,450 4,100 5,700 10,250 17,000 21,000 30,000 2,700 4,500 6,400 10,750 18,000 23,000 35,000 2,900 4,800 6,700 11,500 19,000 24,250 40,000 3,000 5,000 7, 25 0 12,000 19,500 27,000 50,000 3,400 5,250 7,75 0 13,000 21,000 29,000 60,000 3,600 5,750 8,100 14,000 22,000 30,500 80,000 3,900 6,250 9,000 15,000 24,000 33,000 100,000 4,300 6,750 9,750 16,500 26,000 35,000 150,000 4,500 7,6 0 0 11,100 19,000 28,000 38,000 200,000 4,600 8,400 12,250 21,500 30,000 40,000 * prospective rms symmetrical amperes short-circuit current note: data derived from peak let-thru curves flnr_id/flsr_id indicator ? class rk5 fuses 250/600 vac ? dual-element, time delay ? 1/10 C 600 amperes
general purpose fuses general purpose fuses 32 www.littelfuse.com ? 2005 littelfuse ? powr-gard ? products catalog flnr_id/flsr_id indicator ? class rk5 fuses 250/600 vac ? dual-element, time delay ? 1/10 C 600 amperes 600a 400a 200a 100a 60a 30a 15a 5 100 80 60 40 30 20 10 8 6 100000 80000 60000 40000 30000 20000 10000 8000 6000 4000 3000 2000 1000 800 600 400 300 200 .01 .02 .03 .04 .05 .06 .08 .1 .2 .3 .4 .6 .8 1 2 3 4 6 8 10 20 30 40 60 80 100 200 300 400 600 800 1000 current in amperes time in seconds flsr_id 600a 400a 200a 100a 60a 50 1000 800 600 400 300 200 100 80 60 1000000 800000 600000 400000 300000 200000 100000 80000 60000 40000 30000 20000 10000 8000 6000 4000 3000 2000 .01 .02 .03 .04 .06 .08 .1 .2 .3 .4 .6 .8 1 2 3 4 6 8 10 20 30 40 60 80 100 200 300 400 600 800 1000 time in seconds current in amperes flnr_id 60a 100a 200a 400a 600a 1000000 800000 600000 400000 300000 200000 100000 80000 60000 40000 30000 20000 10000 8000 6000 4000 3000 2000 1000 800 600 400 300 200 100 1000 800 600 400 300 200 100 200000 100000 80000 60000 40000 30000 20000 10000 8000 6000 4000 3000 2000 flnr_id peak let - thru in amperes av ailable f aul t current symmetrical r.m.s. amperes 600a 400a 200a 100a 60a 30a 15a 1000000 800000 600000 400000 300000 200000 100000 80000 60000 50000 40000 30000 20000 10000 8000 6000 5000 4000 3000 2000 1000 800 600 400 300 200 100 1000 800 600 400 300 200 100 200000 100000 80000 60000 40000 30000 20000 10000 8000 6000 4000 3000 2000 peak let - thru in amperes ava ilable f aul t current symmetrical r. m. s. amperes flsr_id
|