1 a8m miniature rocker switch miniature rocker switch for high current switching miniature rocker switch can be switching 16a. easy to mount by snap fitting. ul and cul standard approved. conforms to en standards. ordering information ratings note: 1. the inductive load has a power factor of 0.7 minimum (ac). 2. the motor load has an impulse current 6 times the normal current. 3. the above ratings were tested under the following conditions: (1) ambient temperature: 20 2 c (2) ambient humidity: 65 5 %rh (3) switching frequency: 7 times/min. operating characteristics specifications rohs compliant (refer to page 3 for details) caution refer to precautions contact configuration spst dpst quantity per package color of caps and cases black black marking on caps a8ms-1162 a8md-1162 100 a8ms-1163 A8MD-1163 2 3 2 3 5 6 non-inductive inductive rated load resistive load inductive load inductive motor load 125 vac 16 a 16 a 10 a 250 vac 16 a 16 a 10 a no. of poles 1 2 of (operating force) 8 n max. 14 n max. permissible operating frequency mechanical 20 operations / min max. electrical 7 operations / min max. insulation resistance 100 m min. (500 vdc) dielectric strength 2000 vac 50/60hz, for 1min between terminals of the same polarity 4000 vac 50/60hz, for 1min between terminal and case ground. vibration resistance malfunction 10 to 55 hz, 1.5-mm double amplitude shock resistance malfunction 1000 m/s 2 max. life expectancy mechanical 50,000 operations min. electrical 10,000 operations min. ambient operating temperature - 25 to 55 c humidity 60 %rh max. (with no icing or dewing) ambient operating humidity 25 to 85 %rh (for 15 to 35 c) ambient storage temperature - 40 to 85 c (with no icing or dewing) ambient storage humidity 25 to 85 %rh weight 4.5 g (1 pole), 5.9 g (2 poles)
2 a8m a8m approved safety standards ul (ul1054/csa c22.2 no. 55) 16a 125 vac, 16a 250 vac vde (en61058-1) 16a 125 vac, 16a 250 vac note: quick-connect terminals are not in compliance with iec standards. dimensions (unit: mm) panel cutout solder terminal quick-connect terminal (#250 t=0.8) common use quick-connect terminals are not in compliance with iec standards. 9.6 18.5 1.6 dia. 2.8 dia. 21 +0.3 - 0.5 10.7 0.8 12.5 10 16.3 12.9 15 2 15.8 24.1 3.7 2.2 5.6 0.5 2 3 5 6 a8ms-1162 a8ms-1163 a8md-1162 A8MD-1163 note: unless otherwise specified, a tolerance of 0.3 mm applies to all dimensions. xmm ymm r0.3 0.1 edge panel thickness (mm) x (mm) y (mm) 0.75 to 1.25 19.2 12.9 1.26 to 2.00 19.4 2.01 to 3.00 19.8 +0.1 0 +0.1 0 +0.1 0 +0.1 0 be sure that play r or above-mentioned r is the operation side.
3 a8m a8m precautions to increase the reliability of oper ation, test the switch before actual operation. be sure that there is an enough insulation distance between any switch terminal and metal part. mounting ? turn off the power supply before mounting, removing or wiring the switch, or before performing maintenance inspections. failure to do so many result in electric shock. ? easy to mount by snap fitting. ? do not use panels other than ones with the designated thickness and dimensions. remove all burrs from the cutout before installing the switch. otherwise, the switch may malfunction. ? do not impose excessive force on the switch at the time of panelmounting. otherwise the switch may be damaged or deformed, and the switch mechanism may malfunction as a result. wiring ? when soldering terminals manually, perform soldering within 4 s using a soldering iron (temperature at the tip of the soldering iron: 360 c max). do not apply excessive force to the terminals during soldering. ? quick-connect terminals (#250 t=0.8) are not in compliance with iec standards. suitable for use as solder connection. ? be sure that the wires are thick enough for the load (current) to be applied. ? the performance of the switch may be affected if the switch is used for switching micro loads. test the switch under the actual operating conditions. environment for storage and use ? do not use the switch in places with sulfide gas, corrosive gas, sea breeze, oil spray, or direct sunlight. otherwise, the switch may malfunction. ? do not use the switch in places that are visibly dusty. otherwise, the contacts may fail to operate correctly. ? the switches are not sealed, cannot prevent to enter dust particles and liquid perfectly. test the switch under the actual operating conditions before use. handling ? do not drop the switch. otherwise, the switch may malfunction. ? do not impose excessive force on the switch. otherwise, the switch may deform. ? use the switch within the rated voltage and current ranges, otherwise the switch may have a shortened life expectancy, radiate heat, burn out or malfunction. ? do not impose force to operating part from an angle, otherwise the switch may be damaged or deformed. rohs compliant the ?rohs compliant? designation indicates that the listed models do not contain the six hazardous substances covered by the rohs directive. reference: the following standards are used to determine compliance for the six substances. lead : 1000 ppm max. mercury : 1000 ppm max. cadmium : 100 ppm max. hexavalent chromium : 1000 ppm max. pbb : 1000 ppm max. pbde : 1000 ppm max. caution do not wire the switch or touch any terminal of the switch while power is being supplied. doing so may result in electric shock. pushing position case flange
in the interest of product improvement, spec ifications are subject to change without notice. all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0. 03937. to convert grams into ounces, multiply by 0.03527. cat. no. a175-e1-01 printed in japan 1008-1m (1008) omron corporation electronic components company switch division manual switch department shiokoji horikawa, shimogyo-ku, kyoto, 600-8530 japan tel: (81)75-344-7096/fa x: (81)75-344-7188 url : http://www.omron.com/ecb/
|