  Datasheet File OCR Text:
  series am el20 - maz 20 w att | ac- dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.m 1 of 4 north america only features: models single output model input voltage (vac/hz) input voltage (vdc) max output wattage (w) output voltage(v) output current max (a) maximum capacitive load (f) efficiency (%) amel20 - 3.3smaz 90 - 26 4 /47 - 440 120 - 370 13.2 3.3 4 56 00 74 amel20 - 5smaz 90 - 26 4 /47 - 440 120 - 370 20 5 4 47 00 78 amel20 - 12smaz 9 0 - 26 4 /47 - 440 120 - 370 20 12 1. 6 6 33 00 8 2 amel20 - 15smaz 90 - 26 4 /47 - 440 120 - 370 20 15 1.33 22 00 8 2 amel20 - 24smaz 90 - 26 4 /47 - 440 120 - 370 20 24 0. 8 4 1000 8 2 models asymmetric dual output model input voltage (vac/hz) input voltage (vdc) max output wattage (w) output voltage (v) rated o utput current (a) maximum capacitive load (f) efficiency (%) amel20 - 3.35dmaz 90 - 26 4 /47 - 440 120 - 370 17. 5 3.3/5 1.4 / 2. 5 1000 75 amel20 - 3.312dmaz 90 - 26 4 /47 - 440 120 - 370 18 3.3/12 1.4 / 1.1 1000 78 amel20 - 3.315dmaz 90 - 26 4 /47 - 440 120 - 370 18 3.3 /15 1.4 /0. 89 1000 77 amel20 - 3.324dmaz 90 - 26 4 /47 - 440 120 - 370 18 3.3/24 1.4 /0. 55 1000 76 amel20 - 512dmaz 90 - 26 4 /47 - 440 120 - 370 18 5/12 1.6 /0. 8 3 680 76 amel20 - 515dmaz 90 - 26 4 /47 - 440 120 - 370 18 5/15 1.6 /0. 66 680 78 amel20 - 524dmaz 90 - 26 4 /47 - 440 120 - 370 18 5/24 1.6 /0.4 6 680 76 amel20 - 1215dmaz 90 - 26 4 /47 - 440 120 - 370 18 12/15 0. 66 /0. 66 560 77 amel20 - 1224dmaz 90 - 26 4 /47 - 440 120 - 370 18 12/24 0. 58 /0. 4 2 560 79 amel20 - 1524dmaz 90 - 26 4 /47 - 440 120 - 370 18 15/24 0. 54 /0. 4 2 560 80 amel20 - 3.3n5dmaz 90 - 26 4 /47 - 440 120 - 370 14.8 - 3.3/5 - 0.7 / 2. 5 680 75 amel20 - 3.3n12dmaz 90 - 26 4 /47 - 440 120 - 370 18 - 3.3/12 - 1.4 / 1.1 680 76 amel20 - 3.3n15dmaz 90 - 26 4 /47 - 440 120 - 370 18 - 3.3 /15 - 1.4 /0. 89 680 76 amel20 - 5n5dmaz 90 - 26 4 /47 - 440 120 - 370 14 - 5/5 - 0.8 /2 680 75 amel20 - 5n12dmaz 90 - 26 4 /47 - 440 120 - 370 18 - 5/12 - 1.6 /0. 8 3 470 75 amel20 - 5n15dmaz 90 - 26 4 /47 - 440 120 - 370 18 - 5/15 - 1.6 /0. 66 470 75 amel20 - 12n12dmaz 90 - 26 4 /47 - 440 120 - 370 18 - 12/12 - 0.66 /0. 83 470 77 amel20 - 12 n 15dmaz 90 - 26 4 /47 - 440 120 - 370 18 - 12/15 - 0. 66 /0. 66 33 0 76 *output power must not exceed the listed values. note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. i nput specifications parameters conditions typical maximum units current 115vac 0.46 a 230vac 0.29 a inrush current <2ms (cold start) 115vac 10 a 230vac 20 a leakage current 0.2 5 ma external fuse slow blow type 1.5 a ? i/o isolation 4000vac ? energy star compliant ? operating temp: - 40 o c to + 7 0 o c ? ultra small package ? over load, over voltage, short circuit protection ? up to 8 2 % efficiency cb
series am el20 - maz 20 w att | ac- dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.m 2 of 4 north america only i nput specifications (continued) parameters conditions typical maximum units input dissipation no load <0. 5 w start up time 50 ms output specifications parameters conditions typical maximum units voltage accuracy 2 % line regulation 1 % load regulation (single output) 0 - 100% load 2 % load regulation ( dual output) unbalanced ( 0 - 100% ) load 3 % transient recovery time 5 00 s transient response deviation 25% load step 2 % of vout ripple & noise * 3.3 & 5v models 75 mv p -p 12, 15 & 24v models 1 00 hold - up time (min) 110v ac 1 0 ms 230vac 25 * ripple and noise are measured at 20mhz bandwidth by using a 0.1f (m/c) parallel capacitor. isolation specifications parameters conditions typical rated units tested i/o voltage 3 sec , 1.2ma 4000 vac isolation resistance >100 0 m isolation capacitance 2200 pf general specifications parameters conditions typical maximum units switching frequency 100% load 6 5 khz over load protection auto recovery, foldback 1 5 0 % over voltage protection zener diode clamp short circui t protection continuous short circuit restart auto recovery operating temperature see derating table - 40 to + 70 o c maximum case temperature 100 o c storage temperature - 45 to +95 o c temperature coefficient 0.02 % / o c cooling free air convecti on humidity non condensing 20 ~ 95 % rh case material plastic resin + fiberglass (flammability to ul 94v - 0) weight 7 0 g dimensions (l x w x h ) 2 . 22 x 1 . 21 x 0.9 9 inches 5 6.48 x 30.86 x 25.10 mm mtbf > 400 000 hrs (mil - hdbk - 217f, t=+25 o c) env ironment approval test parameters conditions shock wave form half sine wave acceleration amplitude 5gn bump duration 30 ms converter operation before and after test, body mounted (on chassis) number of bumps 18 (3 in each direction for every axi s) vibration test mode sweep sine displacement 1mm acceleration 3g converter operation 10 - 100hz, speed 0.05hz/s
series am el20 - maz 20 w att | ac- dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.m 3 of 4 north america only safety specifications parameters agency approvals culus, ce, cb , tv rheinhald (ctuvus) , bauart - mark s tandards medical electrical equ ipment iec \ en \ ul 60601 - 1 , csa - c22.2 no. 601.1 - m90 information technology equipment en 60950 - 1:2006+a11:2009 emi - conducted and radiated emission en550 11 , class b harmonic current emissions iec/en 61000 - 3 - 2, (en60555 - 2) voltage fluctuations and fli cker iec/en 61000 - 3 - 3, (en60555 - 3) electrostatic discharge immunity iec 61000 - 4 - 2 rf, electromagnetic field immunity iec 61000 - 4 - 3 electrical fast transient/burst immunity iec 61000 - 4 - 4 surge immunity iec 61000 - 4 - 5 rf, conducted disturbance immun ity iec 61000 - 4 - 6 power frequency magnetic field immunity iec 61000 - 4 - 8 voltage dips, short interruptions immunity iec 61000 - 4 - 11 information technology equipment ul 60950 - 1:2007 information technology equipment can/csa - c22.2 no.60950 - 1 - 07 pin ou t specifications dimensions top view 1 2 3 4 5 1.05 (0.04) case tolerance 0.50 (0.02) pin diameter 1.0 0.05 (0.04 0.002) pin pitch tolerance 0.35 (0.014) dimensions mm (inch) 5? 1.0 (? 0.04) div: 10.00 (0.40) 56.46 (2.22) 30.86 (1.21) 20.40 (0.80) 5.37 (0.21) 5.37 (0.21) 5.27 (0.21) 5,27 (0.21) 45.72 (1.80) 10.20 (0.40) 10.20 (0.40) 25.10 (0.99) 8.00 (0.31) top view 1 2 3 4 5 pin single dual positive dual negative/positive 1 ac input (n) ac input (n) ac input (n) 2 ac input (l) ac input (l) ac input (l) 3 +v output +v 1 output + v 1 output 4 - v output common common 5 no pin + v 2 output - v 2 output
series am el20 - maz 20 w att | ac- dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.m 4 of 4 north america only derating - 40 - 20 0 20 40 60 80 100 100 80 60 40 20 0 safe operating area output power (%) ambient temperature o c free air convection 70c 40c note: 1. datasheets are updated as needed and as such, specifications are subject to change without notice. once printed or downloaded, datasheets are no longer controlled by a imtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference on ly. 4. all specifications are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal c omponents and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary and may not be available for release. 6. this product is not designed for use in critical life support systems, equipmen t used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. warranty is in accordance with aimtecs standard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 
Price & Availability of AMEL20-MAZ13

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X