|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
lfa-2 lfa10f ac-dc power supplies open frame/ enclosed type lf a 10 f - o - o ordering information 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional c : with coating g: low leakage current j1 : vh(j.s.t.)connector type s : with chassis sn : with chassis & cover y: with potentiometer specification is changed at option, refer to instruction manual. 1 2 3 4 5 6 this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa10f-3r3-y lfa10f-5 lfa10f-12 lfa10f-15 lfa10f-24 max output wattage[w] 6.6 10 10.8 10.5 12 dc output 3.3v 2a 5v 2a 12v 0.9a 15v 0.7a 24v 0.5a specifications model lfa10f-3r3-y lfa10f-5 lfa10f-12 lfa10f-15 lfa10f-24 input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 3 current[a] acin 100v 0.18typ (io=100%) 0.26typ (io=100%) acin 200v 0.11typ (io=100%) 0.16typ (io=100%) frequency[hz] 50 / 60 (47 - 440) efficiency[%] acin 100v 68.0typ 74.0typ 76.5typ 77.5typ 79.5typ acin 200v 68.5typ 76.0typ 79.0typ 80.0typ 83.0typ inrush current[a] acin 100v 15typ (io=100%) acin 200v 30typ (io=100%) leakage current[ma] 0.15/0.30max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 3.3 5 12 15 24 current[a] 2.0 2.0 0.9 0.7 0.5 line regulation[mv] * 5 20max 20max 48max 60max 96max load regulation[mv] * 5 40max 40max 100max 120max 150max ripple[mvp-p] * 1 0 to +50 c 80max 80max 120max 120max 120max -10 - 0 c 140max 140max 160max 160max 160max io=0 - 35% 190max 160max 240max 240max 280max ripple noise[mvp-p] * 1 0 to +50 c 120max 120max 150max 150max 150max -10 - 0 c 160max 160max 180max 180max 180max io=0 - 35% 240max 240max 300max 300max 320max temperature regulation[mv] 0 to +50 c 50max 50max 120max 150max 240max -10 to +50 c 60max 60max 150max 180max 290max drift[mv] * 2 20max 20max 48max 60max 96max start-up time[ms] 200typ (acin 100v, io=100%) y * start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] 2.85 to 3.63 fixed ( l y z option is available for adjusting output voltage between 10%) output voltage setting[v] 3.30 to 3.40 4.90 to 5.30 11.50 to 12.50 14.40 to 15.60 23.00 to 25.00 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 operating indication not provided remote sensing not provided remote on/off not provided isolation input-output ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output-fg ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) environment operating temp.,humid.and altitude -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2), 3,000m (10,000 feet) max * 3 storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing) , 9,000m (30,000 feet) max vibration 10 - 55hz, 19.6m/s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b ce marking low voltage directive, emc directive harmonic attenuator complies with iec61000-3-2 (class a) * 6 (not built-in to active ?lter) * 4 others case size/weight 50 x 22 x 73.5mm [1.97 x 0.87 x 2.89 inches] (w x h x d) / 55g max (without chassis and cover) cooling method convection (refer to instruction manual 3.1 and 3.2) * 3 * 1 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). a circuit reducing standby power is built in this unit. therefore, the internal switch element is intermittent operated, and the ripple/ripple noise speci?cation in load factor io=0-35% is different. please refer to the instruction manual 1.7. * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 3 derating is required. * 4 when two or more units are operating it may not comply with the iec61000-3-2. please contact us for details. * 5 please contact us about dynamic load and input response. * 6 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. recommended emi/emc filter nac-04-472 high voltage pulse noise type : nap series low leakage current type : nam series * the emi/emc filter is recommended to connect with several devices. lfa o g n h c k p f f . ( #
lfa-3 lfa10f external view block diagram lfa-4 lfa15f ac-dc power supplies open frame/ enclosed type lf a 15 f - ? - ? 0 s e f s j o h j o g p s n b u j p o 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional c : with coating g: low leakage current j1 : vh(j.s.t.)connector type s : with chassis sn : with chassis & cover y: with potentiometer specification is changed at option, refer to instruction manual. this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa15f-3r3-y lfa15f-5 lfa15f-12 lfa15f-15 lfa15f-24 max output wattage[w] 9.9 15 15.6 15 16.8 dc output 3.3v 3a 5v 3a 12v 1.3a 15v 1a 24v 0.7a specifications model lfa15f-3r3-y lfa15f-5 lfa15f-12 lfa15f-15 lfa15f-24 input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 3 current[a] acin 100v 0.24typ (io=100%) 0.35typ (io=100%) acin 200v 0.15typ (io=100%) 0.20typ (io=100%) frequency[hz] 50 / 60 (47 - 440) efficiency[%] acin 100v 68.0typ 73.0typ 76.0typ 77.0typ 78.0typ acin 200v 69.0typ 76.0typ 78.5typ 80.0typ 81.5typ inrush current[a] acin 100v 15typ (io=100%) (at cold start) (ta=25 c ) acin 200v 30typ (io=100%) (at cold start) (ta=25 c ) leakage current[ma] 0.15/0.30max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 3.3 5 12 15 24 current[a] 3.0 3.0 1.3 1.0 0.7 line regulation[mv] * 5 20max 20max 48max 60max 96max load regulation[mv] * 5 40max 40max 100max 120max 150max ripple[mvp-p] * 1 0 to +50 c 80max 80max 120max 120max 120max -10 - 0 c 140max 140max 160max 160max 160max io=0 - 35% 190max 160max 240max 240max 280max ripple noise[mvp-p] * 1 0 to +50 c 120max 120max 150max 150max 150max -10 - 0 c 160max 160max 180max 180max 180max io=0 - 35% 240max 240max 300max 300max 320max temperature regulation[mv] 0 to +50 c 50max 50max 120max 150max 240max -10 to +50 c 60max 60max 150max 180max 290max drift[mv] * 2 20max 20max 48max 60max 96max start-up time[ms] 200typ (acin 100v, io=100%) y * start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] 2.85 to 3.63 fixed ( l y z option is available for adjusting output voltage between 10%) output voltage setting[v] 3.30 to 3.40 4.90 to 5.30 11.50 to 12.50 14.40 to 15.60 23.00 to 25.00 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 operating indication not provided remote sensing not provided remote on/off not provided isolation input-output ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output-fg ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) environment operating temp.,humid.and altitude -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2), 3,000m (10,000 feet) max * 3 storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing) , 9,000m (30,000 feet) max vibration 10 - 55hz, 19.6m/s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b ce marking low voltage directive, emc directive harmonic attenuator complies with iec61000-3-2 (class a) * 6 (not built-in to active ?lter) * 4 others case size/weight 50 x 22 x 87.5mm [1.97 x 0.87 x 3.44 inches] (w x h x d) / 80g max (without chassis and cover) cooling method convection (refer to instruction manual 3.1 and 3.2) * 3 * 1 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). a circuit reducing standby power is built in this unit. therefore, the internal switch element is intermittent operated, and the ripple/ripple noise speci?cation in load factor io=0-35% is different. please refer to the instruction manual 1.7. * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 3 derating is required. * 4 when two or more units are operating it may not comply with the iec61000-3-2. please contact us for details. * 5 please contact us about dynamic load and input response. * 6 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. recommended emi/emc filter nac-04-472 high voltage pulse noise type : nap series low leakage current type : nam series * the emi/emc filter is recommended to connect with several devices. lfa o g n h c k p f f . ( # lfa-5 lfa15f external view block diagram ac in 85 264v noise filter control inverter rectifier and filter rectifier and filter dc out fg transformer control fuse ac250v 2.5a photocoupler photocoupler over voltage protection current sensing inrush current limit lfa-6 lfa30f ac-dc power supplies open frame/ enclosed type lf a 30 f - ? - ? 0 s e f s j o h j o g p s n b u j p o 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional c : with coating g: low leakage current j1 : vh(j.s.t.)connector type s : with chassis sn : with chassis & cover y: with potentiometer specification is changed at option, refer to instruction manual. this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa30f-3r3-y lfa30f-5 lfa30f-12 lfa30f-15 lfa30f-24 max output wattage[w] 19.8 30.0 30.0 30.0 31.2 dc output 3.3v 6a 5v 6a 12v 2.5a 15v 2a 24v 1.3a specifications model lfa30f-3r3-y lfa30f-5 lfa30f-12 lfa30f-15 lfa30f-24 input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 3 current[a] acin 100v 0.50typ (io=100%) 0.65typ (io=100%) acin 200v 0.30typ (io=100%) 0.35typ (io=100%) frequency[hz] 50 / 60 (47 - 440) efficiency[%] acin 100v 73typ 76typ 79typ 81typ 82typ acin 200v 75typ 79typ 81typ 83typ 84typ inrush current[a] acin 100v 15typ (io=100%) (at cold start) (ta=25 c ) acin 200v 30typ (io=100%) (at cold start) (ta=25 c ) leakage current[ma] 0.30 / 0.65max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 3.3 5 12 15 24 current[a] 6.0 6.0 2.5 2.0 1.3 line regulation[mv] * 5 20max 20max 48max 60max 96max load regulation[mv] * 5 40max 40max 100max 120max 150max ripple[mvp-p] 0 to +50 c * 1 80max 80max 120max 120max 120max -10 - 0 c * 1 140max 140max 160max 160max 160max ripple noise[mvp-p] 0 to +50 c * 1 120max 120max 150max 150max 150max -10 - 0 c * 1 160max 160max 180max 180max 180max temperature regulation[mv] 0 to +50 c 50max 50max 120max 150max 240max -10 to +50 c 60max 60max 150max 180max 290max drift[mv] * 2 20max 20max 48max 60max 96max start-up time[ms] 150typ (acin 100v, io=100%) hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] 2.85 to 3.63 fixed ( l y z option is available for adjusting output voltage between 10%) output voltage setting[v] 3.30 to 3.40 4.90 to 5.30 11.50 to 12.50 14.40 to 15.60 23.00 to 25.00 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 operating indication not provided remote sensing not provided remote on/off not provided isolation input-output ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output-fg ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) environment operating temp.,humid.and altitude -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2) , 3,000m (10,000feet) max * 3 storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing), 9,000m (30,000feet) max vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b ce marking low voltage directive, emc directive harmonic attenuator complies with iec61000-3-2 (class a) * 6 (not built-in to active ?lter) * 4 others case size/weight 50 x 26.5 x 105mm [1.97 x 1.04 x 4.13 inches] (w x h x d) / 130g max (without chassis and cover) cooling method convection (refer to instruction manual 3.1 and 3.2) * 3 * 1 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 3 derating is required. * 4 when two or more units are operating it may not comply with the iec61000-3-2. please contact us for details. * 5 please contact us about dynamic load and input response. * 6 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. recommended emi/emc filter nac-04-472 high voltage pulse noise type : nap series low leakage current type : nam series * the emi/emc filter is recommended to connect with several devices. lfa o g n h c k p f f . ( # lfa-7 lfa30f external view block diagram ac in 85 264v noise filter control inverter rectifier and filter rectifier and filter dc out fg transformer control fuse ac250v 3.15a photocoupler photocoupler over voltage protection current sensing inrush current limit lfa-8 lfa50f ac-dc power supplies open frame/ enclosed type lf a 50 f - ? - ? 0 s e f s j o h j o g p s n b u j p o 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional c : with coating g: low leakage current j1 : vh(j.s.t.)connector type s : with chassis sn : with chassis & cover y: with potentiometer specification is changed at option, refer to instruction manual. this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa50f-3r3-y lfa50f-5 LFA50F-12 lfa50f-15 lfa50f-24 lfa50f-36 lfa50f-48 max output wattage[w] 33 50 51.6 52.5 50.4 50.4 52.8 dc output 3.3v 10a 5v 10a 12v 4.3a 15v 3.5a 24v 2.1a 36v 1.4a 48v 1.1a specifications model lfa50f-3r3-y lfa50f-5 LFA50F-12 lfa50f-15 lfa50f-24 lfa50f-36 lfa50f-48 input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 3 current[a] acin 100v 0.47typ (io=100%) 0.67typ (io=100%) acin 200v 0.27typ (io=100%) 0.36typ (io=100%) frequency[hz] 50 / 60 (47 - 63) efficiency[%] acin 100v 73.5typ 77.5typ 80.0typ 80.5typ 81.5typ 82.0typ 81.0typ acin 200v 74.0typ 79.0typ 81.5typ 81.5typ 83.0typ 83.5typ 82.5typ power factor (io=100%) acin 100v 0.96typ 0.97typ acin 200v 0.83typ 0.90typ inrush current[a] acin 100v 15typ (io=100%) (at cold start) (ta=25 c ) acin 200v 30typ (io=100%) (at cold start) (ta=25 c ) leakage current[ma] 0.40 / 0.75max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 3.3 5 12 15 24 36 48 current[a] 10.0 10.0 4.3 3.5 2.1 1.4 1.1 line regulation[mv] * 4 20max 20max 48max 60max 96max 144max 192max load regulation[mv] * 4 40max 40max 100max 120max 150max 240max 240max ripple[mvp-p] 0 to +50 c * 1 80max 80max 120max 120max 120max 150max 150max -10 - 0 c * 1 140max 140max 160max 160max 160max 200max 200max ripple noise[mvp-p] 0 to +50 c * 1 120max 120max 150max 150max 150max 250max 250max -10 - 0 c * 1 160max 160max 180max 180max 180max 300max 300max temperature regulation[mv] 0 to +50 c 50max 50max 120max 150max 240max 360max 480max -10 to +50 c 60max 60max 150max 180max 290max 450max 600max drift[mv] * 2 20max 20max 48max 60max 96max 144max 192max start-up time[ms] 350typ (acin 100v, io=100%) hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] 2.85 to 3.63 fixed ( l y z option is available for adjusting output voltage between 10%) output voltage setting[v] 3.30 to 3.40 4.90 to 5.30 11.50 to 12.50 14.40 to 15.60 23.00 to 25.00 34.50 to 37.50 46.00 to 50.00 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 operating indication not provided remote sensing not provided remote on/off not provided isolation input-output ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output-fg ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) environment operating temp.,humid.and altitude -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2) , 3,000m (10,000feet) max * 3 storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing), 9,000m (30,000feet) max vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b ce marking low voltage directive, emc directive harmonic attenuator complies with iec61000-3-2 (class a) * 5 others case size/weight 50 x 26.5 x 132mm [1.97 x 1.04 x 5.20 inches] (w x h x d) / 165g max (without chassis and cover) cooling method convection (refer to instruction manual 3.1 and 3.2) * 3 * 1 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 3 derating is required. * 4 please contact us about dynamic load and input response. * 5 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. recommended emi/emc filter nac-04-472 high voltage pulse noise type : nap series low leakage current type : nam series * the emi/emc filter is recommended to connect with several devices. lfa o g n h c k p f f . ( # lfa-9 lfa50f external view block diagram fg filter noise ac in 85 264v fuse rectifier current sensing booster inductor inverter control 250v2.5a control inverter dc out transformer control photocoupler photocoupler over voltage protection current sensing inrush current limit rectifier and filter rectifier and filter lfa-10 lfa75f ac-dc power supplies open frame/ enclosed type lf a 75 f - ? - ? 0 s e f s j o h j o g p s n b u j p o 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional c : with coating g: low leakage current j1 : vh(j.s.t.)connector type s : with chassis sn : with chassis & cover y: with potentiometer specification is changed at option, refer to instruction manual. this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa75f-3r3-y lfa75f-5 lfa75f-12 lfa75f-15 lfa75f-24 lfa75f-36 lfa75f-48 max output wattage[w] 49.5 75 75.6 75 76.8 75.6 76.8 dc output 3.3v 15a 5v 15a 12v 6.3a 15v 5a 24v 3.2a 36v 2.1a 48v 1.6a specifications model lfa75f-3r3-y lfa75f-5 lfa75f-12 lfa75f-15 lfa75f-24 lfa75f-36 lfa75f-48 input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 3 current[a] acin 100v 0.70typ (io=100%) 1.00typ (io=100%) acin 200v 0.40typ (io=100%) 0.50typ (io=100%) frequency[hz] 50 / 60 (47 - 63) efficiency[%] acin 100v 73.5typ 78.0typ 81.5typ 81.5typ 82.5typ 82.5typ 82.5typ acin 200v 75.0typ 80.0typ 83.0typ 83.0typ 84.5typ 84.5typ 84.5typ power factor (io=100%) acin 100v 0.96typ 0.97typ acin 200v 0.83typ 0.90typ inrush current[a] acin 100v 15typ (io=100%) (at cold start) (ta=25 c ) acin 200v 30typ (io=100%) (at cold start) (ta=25 c ) leakage current[ma] 0.40 / 0.75max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 3.3 5 12 15 24 36 48 current[a] 15.0 15.0 6.3 5.0 3.2 2.1 1.6 line regulation[mv] * 4 20max 20max 48max 60max 96max 144max 192max load regulation[mv] * 4 40max 40max 100max 120max 150max 240max 240max ripple[mvp-p] 0 to +50 c * 1 80max 80max 120max 120max 120max 150max 150max -10 - 0 c * 1 140max 140max 160max 160max 160max 200max 200max ripple noise[mvp-p] 0 to +50 c * 1 120max 120max 150max 150max 150max 250max 250max -10 - 0 c * 1 160max 160max 180max 180max 180max 300max 300max temperature regulation[mv] 0 to +50 c 50max 50max 120max 150max 240max 360max 480max -10 to +50 c 60max 60max 150max 180max 290max 450max 600max drift[mv] * 2 20max 20max 48max 60max 96max 144max 192max start-up time[ms] 350typ (acin 100v, io=100%) hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] 2.85 to 3.63 fixed ( l y z option is available for adjusting output voltage between 10%) output voltage setting[v] 3.30 to 3.40 4.90 to 5.30 11.50 to 12.50 14.40 to 15.60 23.00 to 25.00 34.50 to 37.50 46.00 to 50.00 protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 operating indication not provided remote sensing not provided remote on/off not provided isolation input-output ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output-fg ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) environment operating temp.,humid.and altitude -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2) , 3,000m (10,000feet) max * 3 storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing), 9,000m (30,000feet) max vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b ce marking low voltage directive, emc directive harmonic attenuator complies with iec61000-3-2 (class a) * 5 others case size/weight 50 x 33.5 x 150mm [1.97 x 1.32 x 5.91 inches] (w x h x d) / 230g max (without chassis and cover) cooling method convection (refer to instruction manual 3.1 and 3.2) * 3 * 1 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 3 derating is required. * 4 please contact us about dynamic load and input response. * 5 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. recommended emi/emc filter nac-04-472 high voltage pulse noise type : nap series low leakage current type : nam series * the emi/emc filter is recommended to connect with several devices. lfa o g n h c k p f f . ( # lfa-11 lfa75f external view block diagram fg filter noise ac in 85 264v fuse rectifier current sensing booster inductor inverter control 250v3.15a control inverter dc out transformer control photocoupler photocoupler over voltage protection current sensing inrush current limit rectifier and filter rectifier and filter lfa-12 lfa100f ac-dc power supplies open frame/ enclosed type lf a 100 f - ? - ? 0 s e f s j o h j o g p s n b u j p o 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional * 1 c : with coating g: low leakage current h: with the function to be acceptable to output peak current (only 24v) j1 : vh(j.s.t.)connector type r: with remote on/off r2 : with remote on/off s : with chassis sn : with chassis & cover y: with potentiometer this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa100f-3r3-y lfa100f-5-y lfa100f-12 lfa100f-15 lfa100f-24 lfa100f-24-h lfa100f-36 lfa100f-48 max output wattage[w] * 5 66 100 102 100.5 103.2 103.2 (129.6) 100.8 100.8 dc output * 5 3.3v 20a 5v 20a 12v 8.5a 15v 6.7a 24v 4.3a 24v 4.3 (5.4)a 36v 2.8a 48v 2.1a specifications model lfa100f-3r3-y lfa100f-5-y lfa100f-12 lfa100f-15 lfa100f-24 lfa100f-24-h lfa100f-36 lfa100f-48 input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 4 current[a] acin 100v 0.9typ io=100% 1.3typ (io=100%) acin 200v 0.5typ io=100% 0.7typ (io=100%) frequency[hz] 50 / 60 (47 - 63) efficiency[%] acin 100v 77.0typ 82.0typ 82.0typ 83.0typ 84.0typ 84.0typ 84.0typ 84.5typ acin 200v 79.0typ 84.0typ 84.5typ 85.5typ 87.0typ 87.0typ 87.0typ 87.0typ power factor (io=100%) acin 100v 0.98typ 0.99typ acin 200v 0.92typ 0.95typ inrush current[a] acin 100v 15typ (io=100%) (at cold start) (ta=25 c ) acin 200v 30typ (io=100%) (at cold start) (ta=25 c ) leakage current[ma] 0.40 / 0.75max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 3.3 5 12 15 24 24 36 48 current[a] * 5 20 20 8.5 6.7 4.3 4.3 (peak 5.4) 2.8 2.1 line regulation[mv] * 7 20max 20max 48max 60max 96max 96max 144max 192max load regulation[mv] * 7 40max 40max 100max 120max 150max 150max 240max 240max ripple[mvp-p] 0 to +50 c * 2 80max 80max 120max 120max 120max 240max 150max 150max -10 - 0 c * 2 140max 140max 160max 160max 160max 320max 200max 200max ripple noise[mvp-p] 0 to +50 c * 2 120max 120max 150max 150max 150max 300max 250max 250max -10 - 0 c * 2 160max 160max 180max 180max 180max 360max 300max 300max temperature regulation[mv] 0 to +50 c 50max 50max 120max 150max 240max 240max 360max 480max -10 to +50 c 60max 60max 150max 180max 290max 290max 450max 600max drift[mv] * 3 20max 20max 48max 60max 96max 96max 144max 192max start-up time[ms] 350typ (acin 100v, io=100%) hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] 2.85 to 3.63 4.50 to 5.50 fixed ( l y z option is available for adjusting output voltage) output voltage setting[v] 3.30 to 3.40 5.00 to 5.15 11.50 to 12.50 14.40 to 15.60 23.00 to 25.00 23.00 to 25.00 34.50 to 37.50 46.00 to 50.00 protection circuit and others overcurrent protection works over 105% of rating (works over 101% of peak current at option -h) and recovers automatically overvoltage protection 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 operating indication not provided remote sensing not provided remote on/off option (refer to instruction manual) isolation input-output . rc * 6 ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output . rc-fg * 6 ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) output-rc * 6 ac100v 1minute, cutoff current = 25ma, dc100v 10m w min (at room temperature) environment operating temp.,humid.and altitude * 4 -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2) , 3,000m (10,000feet) max storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing), 9,000m (30,000feet) max vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b harmonic attenuator complies with iec61000-3-2 (class a) * 8 others case size/weight 62 x 33.5 x 155mm [2.44 x 1.32 x 6.10 inches] (w x h x d) / 280g max (without chassis and cover) cooling method convection (refer to instruction manual 3.1 and 3.2) * 4 recommended emi/emc filter nac-04-472 high voltage pulse noise type : nap series low leakage current type : nam series * the emi/emc filter is recommended to connect with several devices. * 1 speci?cation is changed at option, refer to instruction manual. * 2 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 3 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 4 derating is required. * 5 ( ) means peak current. there is a possibility that an internal device is damaged when the speci?cation is exceeded. please contact us about the detail. * 6 applicable when remote on/off (optional) is added. * 7 please contact us about dynamic load and input response. * 8 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. please refer to instruction manual 5. lfa o g n h c k p f f . ( # lfa-13 external view block diagram lfa100f ? tolerance : 1 [ 0.04] ? optional chassis and cover material : electric galvanizing steel board. ? weight : 280g max (without chassis and cover) ? pcb material : cem3 ? dimensions in mm, [ ]=inches standard type chassis and cover type ? 4 mounting holes are existing. ? the back side of p.c.b. of the power supply is assembled some smds. be attention not to bump against the attached area by vibration. ? use the spacer of 8mm length or more regarding insulation. and do not use press-fitting bush. ? point a, point b are thermometry points. please refer to instruction manual 3. barrier strip type model b2b-xh-a mating connector (terminal) rc(-) rc(+) 2 1 contents pin no. or sxh-001t-p0.6 bxh-001t-p0.6 xhp-2 cn4 option (mfr:j.s.t) connector type lfa-14 lfa150f ac-dc power supplies open frame/ enclosed type lf a 150 f - ? - ? 0 s e f s j o h j o g p s n b u j p o 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional * 1 c : with coating g: low leakage current h: with the function to be acceptable to output peak current (only 24v) j1 : vh(j.s.t.)connector type r: with remote on/off r2 : with remote on/off s : with chassis sn : with chassis & cover y: with potentiometer this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa150f-3r3-y lfa150f-5-y lfa150f-12 lfa150f-15 lfa150f-24 lfa150f-24-h lfa150f-36 lfa150f-48 max output wattage[w] * 5 99 150 150 150 151.2 151.2 (189.6) 151.2 153.6 dc output * 5 3.3v 30a 5v 30a 12v 12.5a 15v 10a 24v 6.3a 24v 6.3 (7.9)a 36v 4.2a 48v 3.2a specifications model lfa150f-3r3-y lfa150f-5-y lfa150f-12 lfa150f-15 lfa150f-24 lfa150f-24-h lfa150f-36 lfa150f-48 input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 4 current[a] acin 100v 1.4typ io=100% 2.0typ io=100% acin 200v 0.7typ io=100% 1.0typ io=100% frequency[hz] 50 / 60 (47 - 63) efficiency[%] acin 100v 80.0typ 82.5typ 82.5typ 84.0typ 85.0typ 85.0typ 85.0typ 85.5typ acin 200v 82.0typ 85.5typ 85.0typ 86.5typ 87.5typ 87.5typ 87.5typ 88.0typ power factor (io=100%) acin 100v 0.98typ 0.99typ acin 200v 0.92typ 0.95typ inrush current[a] acin 100v 15typ (io=100%) (at cold start) (ta=25 c ) acin 200v 30typ (io=100%) (at cold start) (ta=25 c ) leakage current[ma] 0.40 / 0.75max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 3.3 5 12 15 24 24 36 48 current[a] * 5 30 30 12.5 10 6.3 6.3 (peak 7.9) 4.2 3.2 line regulation[mv] * 7 20max 20max 48max 60max 96max 96max 144max 192max load regulation[mv] * 7 40max 40max 100max 120max 150max 150max 240max 240max ripple[mvp-p] 0 to +40 c * 2 80max 80max 120max 120max 120max 240max 150max 150max -10 - 0 c * 2 140max 140max 160max 160max 160max 320max 200max 200max ripple noise[mvp-p] 0 to +40 c * 2 120max 120max 150max 150max 150max 300max 250max 250max -10 - 0 c * 2 160max 160max 180max 180max 180max 360max 300max 300max temperature regulation[mv] 0 to +40 c 50max 50max 120max 150max 240max 240max 360max 480max -10 to +40 c 60max 60max 150max 180max 290max 290max 450max 600max drift[mv] * 3 20max 20max 48max 60max 96max 96max 144max 192max start-up time[ms] 350typ (acin 100v, io=100%) hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] 2.85 to 3.63 4.50 to 5.50 fixed ( l y z option is available for adjusting output voltage) output voltage setting[v] 3.30 to 3.40 5.00 to 5.15 11.50 to 12.50 14.40 to 15.60 23.00 to 25.00 23.00 to 25.00 34.50 to 37.50 46.00 to 50.00 protection circuit and others overcurrent protection works over 105% of rating (works over 101% of peak current at option -h) and recovers automatically overvoltage protection 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 operating indication not provided remote sensing not provided remote on/off option (refer to instruction manual) isolation input-output . rc * 6 ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output . rc-fg * 6 ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) output-rc * 6 ac100v 1minute, cutoff current = 25ma, dc100v 10m w min (at room temperature) environment operating temp.,humid.and altitude * 4 -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2) , 3,000m (10,000feet) max storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing), 9,000m (30,000feet) max vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b harmonic attenuator complies with iec61000-3-2 (class a) * 8 others case size/weight 75 x 37.0 x 160mm [2.95 x 1.46 x 6.30 inches] (w x h x d) / 390g max (without chassis and cover) cooling method convection (refer to instruction manual 3.1 and 3.2) * 4 recommended emi/emc filter nac-04-472 high voltage pulse noise type : nap series low leakage current type : nam series * the emi/emc filter is recommended to connect with several devices. please refer to instruction manual 5. * 1 speci?cation is changeed at option, refer to instruction manual. * 2 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 3 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 4 derating is required. * 5 ( ) means peak current. there is a possibility that an internal device is damaged when the speci?cation is exceeded. please contact us about the detail. * 6 applicable when remote control (optional) is added. * 7 please contact us about dynamic load and input response. * 8 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. lfa o g n h c k p f f . ( # lfa-15 external view block diagram lfa150f ? tolerance : 1 [ 0.04] ? optional chassis and cover material : electric galvanizing steel board. ? dimensions in mm, [ ]=inches standard type chassis and cover type ? 4 mounting holes are existing. ? the back side of p.c.b. of the power supply is assembled some smds. be attention not to bump against the attached area by vibration. ? use the spacer of 8mm length or more regarding insulation. and do not use press-fitting bush. ? point a, point b are thermometry points. please refer to instruction manual 3. lfa-16 lfa240f ac-dc power supplies open frame/ enclosed type lf a 240 f - ? - ? 0 s e f s j o h j o g p s n b u j p o 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional * 1 c : with coating g: low leakage current h: with the function to be acceptable to output peak current (only 24v) j1 : vh(j.s.t.)connector type r: with remote on/off r2 : with remote on/off s : with chassis sn : with chassis & cover t : vertical terminal block y: with potentiometer this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa240f-24 lfa240f-24-h lfa240f-36 lfa240f-48 max output wattage[w] * 5 240 240 (300) 241.2 240 dc output * 5 24v 10a 24v 10 (12.5)a 36v 6.7a 48v 5a specifications model lfa240f-24 lfa240f-24-h lfa240f-36 lfa240f-48 input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 4 current[a] acin 100v 3.3typ io=100% acin 200v 1.7typ io=100% frequency[hz] 50 / 60 (47 - 63) efficiency[%] acin 100v 84.5typ 84.5typ 84.5typ 84.5typ acin 200v 87.5typ 87.5typ 87.5typ 87.5typ power factor (io=100%) acin 100v 0.99typ acin 200v 0.95typ inrush current[a] acin 100v 15 / 30typ (io=100%) (primary inrush current /secondary inrush current) (more then 3 sec. to re-start) acin 200v 30 / 30typ (io=100%) (primary inrush current /secondary inrush current) (more then 3 sec. to re-start) leakage current[ma] 0.40 / 0.75max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 24 24 36 48 current[a] * 5 10 10 (peak12.5) 6.7 5 line regulation[mv] * 7 96max 96max 144max 192max load regulation[mv] * 7 150max 150max 240max 240max ripple[mvp-p] 0 to +40 c * 2 120max 240max 150max 150max -10 - 0 c * 2 160max 320max 200max 200max ripple noise[mvp-p] 0 to +40 c * 2 150max 300max 250max 250max -10 - 0 c * 2 180max 360max 300max 300max temperature regulation[mv] 0 to +40 c 240max 240max 360max 480max -10 to +40 c 290max 290max 450max 600max drift[mv] * 3 96max 96max 144max 192max start-up time[ms] 350typ (acin 100v, io=100%) hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] fixed ( l y z option is available for adjusting output voltage) output voltage setting[v] 23.00 to 25.00 23.00 to 25.00 34.50 to 37.50 46.00 to 50.00 protection circuit and others overcurrent protection works over 105% of rating (works over 101% of peak current at option -h) and recovers automatically overvoltage protection 27.60 to 33.60 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 operating indication not provided remote sensing not provided remote on/off option (refer to instruction manual) isolation input-output . rc * 6 ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output . rc-fg * 6 ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) output-rc * 6 ac100v 1minute, cutoff current = 25ma, dc100v 10m w min (at room temperature) environment operating temp.,humid.and altitude * 4 -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2) , 3,000m (10,000feet) max storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing), 9,000m (30,000feet) max vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b harmonic attenuator complies with iec61000-3-2 (class a) * 8 others case size/weight 84 x 46.5 x 180mm [3.31 x 1.83 x 7.09 inches] (w x h x d) / 550g max (without chassis and cover) cooling method convection (refer to instruction manual 3.1 and 3.2) * 4 recommended emi/emc filter nac-06-472 high voltage pulse noise type : nap series low leakage current type : nam series * 1 speci?cation is changeed at option, refer to instruction manual. * 2 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 3 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 4 derating is required. * 5 ( ) means peak current. there is a possibility that an internal device is damaged when the speci?cation is exceeded. please contact us about the detail. * 6 applicable when remote control (optional) is added. * 7 please contact us about dynamic load and input response. * 8 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. please refer to instruction manual 5. lfa o g n h c k p f f . ( # lfa-17 external view block diagram lfa240f ? tolerance : 1 [ 0.04] ? optional chassis and cover material : electric galvanizing steel board. ? dimensions in mm, [ ]=inches standard type chassis and cover type ? 5 mounting holes are existing. ? the back side of p.c.b. of the power supply is assembled some smds. be attention not to bump against the attached area by vibration. ? use the spacer of 8mm length or more regarding insulation. and do not use press-fitting bush. ? point a, point b are thermometry points. please refer to instruction manual 3. lfa-18 lfa300f ac-dc power supplies open frame/ enclosed type lf a 300 f - ? - ? 0 s e f s j o h j o g p s n b u j p o 1 2 3 4 5 6 1 series name 2 single output 3 output wattage 4 universal input 5 output voltage 6 optional * 1 c : with coating g: low leakage current h: with the function to be acceptable to output peak current (only 24v, 30v, 36v and 48v) j : ep (tyco electronics) connector type (except 3.3v and 5v) j1 : vh (j.s.t.) connector type (except 3.3v and 5v) r: with remote on/off r2 : with remote on/off s : with chassis snf : with chassis & cover & fan (only 5v, 12v and 24v) t1 : holizontal terminal block this power supply is manufactured by smd technology. the stress to p.c.b like twisting or bending causes the defect of the unit , so handle the unit with care. model lfa300f-3r3-ty lfa300f-5-ty lfa300f-12-ty lfa300f-15-ty lfa300f-24-ty lfa300f-24-hty lfa300f-30-ty lfa300f-36-ty lfa300f-48-ty max output wattage[w] * 5 198 300 324 330 336 336 (456) 330 338.4 336 dc output * 5 convection 3.3v 40a 5v 40a 12v 17a 15v 14a 24v 12.5a 24v 12.5 (19)a 30v 10a 36v 8.4a 48v 6.3a forced air 3.3v 60a 5v 60a 12v 27a 15v 22a 24v 14a 24v 14 (19)a 30v 11a 36v 9.4a 48v 7a specifications model lfa300f-3r3-ty lfa300f-5-ty lfa300f-12-ty lfa300f-15-ty lfa300f-24-ty lfa300f-24-hty lfa300f-30-ty lfa300f-36-ty lfa300f-48-ty input voltage[v] ac85 - 264 1 f (refer to instruction manual 1.1 and 3.2) * 4 current[a] acin 100v 2.7typ io=100% 4.1typ io=100% acin 200v 1.4typ io=100% 2.0typ io=100% frequency[hz] 50 / 60 (47 - 63) efficiency[%] acin 100v 75.0typ 79.0typ 80.0typ 81.5typ 85.0typ 85.0typ 85.5typ 85.5typ 85.5typ acin 200v 77.0typ 82.5typ 83.0typ 84.5typ 88.0typ 88.0typ 88.0typ 88.0typ 88.0typ power factor (io=100%) acin 100v 0.98typ 0.99typ acin 200v 0.92typ 0.95typ inrush current[a] acin 100v 15 / 30typ (io=100%) (primary inrush current /secondary inrush current) (more then 3 sec. to re-start) acin 200v 30 / 30typ (io=100%) (primary inrush current /secondary inrush current) (more then 3 sec. to re-start) leakage current[ma] 0.45 / 0.75max (acin 100v / 240v 60hz, io=100%, according to iec60950-1 and den-an) output voltage[v] 3.3 5 12 15 24 24 30 36 48 current[a] * 5 convection 40 40 17 14 12.5 12.5 (peak19) 10 8.4 6.3 forced air 60 60 27 22 14 14 (peak19) 11 9.4 7 line regulation[mv] * 7 20max 20max 48max 60max 96max 96max 144max 144max 192max load regulation[mv] * 7 40max 40max 100max 120max 150max 150max 240max 240max 240max ripple[mvp-p] 0 to +40 c * 2 80max 80max 120max 120max 120max 240max 150max 150max 150max -10 - 0 c * 2 140max 140max 160max 160max 160max 320max 200max 200max 200max ripple noise[mvp-p] 0 to +40 c * 2 120max 120max 150max 150max 150max 300max 250max 250max 250max -10 - 0 c * 2 160max 160max 180max 180max 180max 360max 300max 300max 300max temperature regulation[mv] 0 to +40 c 50max 50max 120max 150max 240max 240max 360max 360max 480max -10 to +40 c 60max 60max 150max 180max 290max 290max 450max 450max 600max drift[mv] * 3 20max 20max 48max 60max 96max 96max 144max 144max 192max start-up time[ms] 350typ (acin 100v, io=100%) hold-up time[ms] 20typ (acin 100v, io=100%) output voltage adjustment range[v] 2.85 to 3.63 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 27.50 21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80 output voltage setting[v] 3.30 to 3.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92 protection circuit and others overcurrent protection works over 105% of rating (works over 101% of peak current at option -h) and recovers automatically overvoltage protection 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20 operating indication not provided remote sensing not provided remote on/off option (refer to instruction manual) isolation input-output . rc * 6 ac3,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) input-fg ac2,000v 1minute, cutoff current = 10ma, dc500v 50m w min (at room temperature) output . rc-fg * 6 ac500v 1minute, cutoff current = 25ma, dc500v 50m w min (at room temperature) output-rc * 6 ac100v 1minute, cutoff current = 25ma, dc100v 10m w min (at room temperature) environment operating temp.,humid.and altitude * 4 -10 to +70 c , 20 - 90%rh (non condensing) (refer to instruction manual 3.2) , 3,000m (10,000feet) max storage temp.,humid.and altitude -20 to +75 c , 20 - 90%rh (non condensing), 9,000m (30,000feet) max vibration 10 - 55hz, 19.6m/ s 2 (2g), 3minutes period, 60minutes each along x, y and z axis impact 196.1m/s 2 (20g), 11ms, once each x, y and z axis safety and noise regulations agency approvals ul60950-1, c-ul (csa60950-1), en60950-1, en50178 complies with den-an conducted noise complies with fcc-b, vcci-b, cispr-b, en55011-b, en55022-b harmonic attenuator complies with iec61000-3-2 (class a) * 8 others case size/weight 95 x 52.5 x 222mm [3.74 x 2.07 x 8.74 inches] (w x h x d) (without terminal block) / 810g max cooling method convection / forced air (refer to instruction manual 3.1 and 3.2) * 4 recommended emi/emc filter nac-06-472 high voltage pulse noise type : nap series low leakage current type : nam series * 1 speci?cation is changeed at option, refer to instruction manual. * 2 this is the value that measured on measuring board with capacitor of 22 m f at 150mm from output terminal. measured by 20mhz oscilloscope or ripple-noise meter (equivalent to keisoku-giken: rm103). * 3 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 4 derating is required. * 5 ( ) means peak current. there is a possibility that an internal device is damaged when the speci?cation is exceeded. please contact us about the detail.. * 6 applicable when remote control (optional) is added. * 7 please contact us about dynamic load and input response. * 8 please contact us about another class. * to meet the speci?cations. do not operate over-loaded condition. * parallel operation is not possible. * derating is required when operated with chassis and cover. * sound noise may be generated by power supply in case of pulse load. please refer to instruction manual 5. lfa o g n h c k p f f . ( # lfa-19 external view block diagram lfa300f ? external size of option is different from standard model. standard type ? 5 mounting holes are existing. ? the back side of p.c.b. of the power supply is assembled some smds. be attention not to bump against the attached area by vibration. ? use the spacer of 8mm length or more regarding insulation. and do not use press-fitting bush. ? point a, point b, point c, point d are thermometry points. please refer to instruction manual 3. ? keep drawing current per pin below 20a for tb2. barrier strip type model b2b-xh-a mating connector (terminal) rc(-) rc(+) 2 1 contents pin no. or sxh-001t-p0.6 bxh-001t-p0.6 xhp-2 cn4 option (mfr:j.s.t) connector type output(+) output(-) tb2 m4 m4 input(n) fg input(l) tb1 point d point c connector for remote on/off (optional) cn4 point b point a pcb t=1.6 voltage adjust mounting hole 4- f 3.5 mounting hole name plate 2 1 18.5 10 8.6 222 52.5 8.6 10 5 109 0.5 212 0.5 5.5 46.5 85 0.5 5 95 49 4 3.5max 3.5 ? tolerance : 1 [ 0.04] ? dimensions in mm, [ ]=inches ? screw tightening torque : m4 1.6n - m (16.9kgf - cm) max ? weight : 810g max (without chassis and cover) ? pcb material : cem3 fg ? 1 surface mount device ? 1 [0.2] [1.83] [0.16] [0.2] [2.07] [0.39] [0.34] [3.74] [1.93] [0.14] [0.14] [0.22] [0.73] [0.39] [0.34] [8.74] [4.29] [8.35] [3.35] fg dc out ac in 85 - 264v rc e inrush current limit rectifier and filter control transformer control over voltage protection noise filter rectifier and filter inverter rectifier current sensing booster inducter inverter control current sensing external source option 250v10a fuse photocoupler photocoupler photocoupler lfa o g n h c k p f f . ( # |
Price & Availability of LFA50F-12 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |