diesel generator set air ch arge- air c ooling 650 kva / 50 hz / standby (fuel-optimized) 380 - 415v (reference dp590d5s C fuel optimized and dp590d5s C exhaust optimized for prime rating technical data) sy ste m r atings ? standby ds650d5s ds650d5s ds650d5s voltage (l-l) 380v 400v 415v phase 3 3 3 pf 0.8 0.8 0.8 hz 50 50 50 kw 520 520 520 kva 650 650 650 amps 988 938 904 generator model 573rsl7733 573rsl7733 573rsl7733 temp rise 150 c/40c 150 c/40c 150 c/40c connection 4 lead wye 4 lead wye 4 lead wye // low installation cost // best fuel consumption values // long maintenance intervals // h igh-effciency components // best-in-class reliability and availability b enefits optional equipment shown. standard equipment may vary. ? power available up to 40c/400 m
2 /// / 50 hz 650 kva // engine air cleaners oil pump oil drain extension & s/o valve full fow oil flters c losed crankcase ventilation jacket water pump thermostat exhaust manifold C dry blower fan & fan drive radiator C unit mounted electric starting motor C 24v governor C electronic isochronous base C formed steel sae fywheel & bell housing c harging alternator C 24v flexible fuel connectors fuel system: common rail // customer interface smart connect // generator nema m g1, ieee and ansi standards compliance for temperature rise and motor starting vde 0530, iec 34.1, bs 5000, c sa c 22.2-100, as 1359 sustained short circuit current of up to 300% of the rated current for up to 10 seconds self-ventilated superior voltage waveform digital, solid state, volts-per-hertz regulator no load to full load regulation brushless alternator with brushless pilot exciter 4 pole, rotating feld 150 c maximum standby temperature rise 1 bearing, sealed flexible coupling full amortisseur windings 125% rotor balancing 3-phase voltage sensing 0.25% voltage regulation 100% of rated load C one step 3% maximum harmonic content insulation class h protection class ip20 standard equip ment ? ? represents standard product only. consult factory/mtu onsite energy distributor for additional confgurations. // engine-generator set is designed and manufactured in facilities certifed to standards iso 9001:2008 and iso 14001:2004 // performance assurance c ertification (pa c) - engine-generator set tested according to iso 8528-5 for transient response - verifed product design, quality and performance integrity - all engine systems are prototype and factory tested // power rating - permissible average power output during 24 hours of operation up to 85% c ertific ations and standards
3 /// / 50 hz 650 kva // engine m anufacturer mtu model 12v1600g70f type 4-c ycle arrangement 12-v displacement/cylinder: l (cu in) 21 (1,281) bore: mm (in) 122 (4.8) stroke: mm (in) 150 (5.91) c ompression ratio 17.5:1 rated speed rpm 1500 engine governor electronic isochronous m ax power: kwm (bhp) 576 (772) speed regulation 0.25% air flter dry // lube oil capacity total oil system: l (gal) 73 (19.3) // electrical electric volts d c 24 c old cranking amps under -17.8c (0f) 1000 // fuel system fuel supply connection size ? m 22 x 1.5 male fuel return connection size ? m 16 x 1.5 male m aximum fuel lift: m (ft) 5 (16) recommended fuel see mtu fuids & lubrication spec. total fuel fow: l/hr (gal/hr) 341.8 (90.3) // fuel consumption standb y at 100% of power rating: l/hr (gal/hr) 129.8 (34.3) at 75% of power rating: l/hr (gal/hr) 99.9 (26.4) at 50% of power rating: l/hr (gal/hr) 69.6 (18.4) // cooling/radiator system standb y ambient capacity of radiator: c (f) 50 (122) m ax. restriction of cooling air, intake, and discharge side of rad.: kpa (in. h 2 0) 0,2 (0,803) water pump capacity: l/min (gpm) 433 (115) h eat rejection to coolant: kw (btum) 236 (13,421) h eat rejection to after cooler: kw (btu m ) 104 (5,914) h eat radiated to ambient: kw (btum) 59.4 (3,378) engine coolant capacity: l (gal) 65 (17,2) radiator coolant capacity: l (gal) 41 (10,8) c oolant to cooler temperature: c (f) 95 (203) // air requirements ? standb y aspirating: m 3 /min (scfm) 48 (1,695) air fow required for rad. cooled unit: m 3 /min (scfm) 803 (28,350) remote cooled applications; air fow required for dissipation of radiated gen-set heat for a max of 25f rise: m 3 /min (scfm) 216 (7,618) // exhaust system standb y gas temp. (stack): c (f) 484 (903) gas volume at stack temp: m 3 /min (cfm) 126 (4,450) m aximum allowable back pressure: kpa (in. h 2 0) 15 (60.2) applic ation data // the generator set complies to g2 // engine-generator set tested to iso 8528-5 for transient response // accepts rated load in one step per nfpa 110 // all engine-generator sets are protoype and factory tested // m tu onsite energy is a single source supplier // global product support // 2 year standard warranty // c ooling system 50c (integral set-mounted; engine driven fan) // 12v1600 diesel engine (21,0 liter displacement; common rail fuel injection; 4-cycle) // engine-generator resiliently mounted // c omplete range of accessories // brushless, rotating feld generator (p m g excitation; 300% short circuit capability; 2/3 pitch stator windings) // terminal box s tandard f eatures ? ? represents standard product only. consult factory/mtu onsite energy distributor for additional confgurations. ? air density = 1.184 kg/m 3 (0.0739 lbm/ft 3 )
4 /// / 50 hz 650 kva subject to change. | 3236001 | edition 01/14 | en c 2014-02. mtu onsite energy a rolls-royce power systems brand www.mtuonsiteenergy.com weigh ts and dimensions system dimensions (l x w x h) weight (dry) open power unit (opu) 3715 x 1900 x 2047 mm (146.26 x 74.80 x 80.59 in) 4545 kg (10,020 lbs) m aterials and specifcations subject to change without notice. weights and dimensions are based on open power units and are estimates only. c onsult the factory for accurate weights and dimensions for your specifc engine-generator set. drawing above for illustration purposes only, based an standard open power 400 volt engine-generator set. lengths may vary with other voltages. do not use for installation design. see website for unit specifc template drawings. sound data // c onsult your local m tu onsite energy distributor for sound data. emissions data // c onsult your local m tu onsite energy distributor for emissions data. r ating definitions and c onditions // standby ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads for the duration of a power outage. no overload capability for this rating. ratings are in accordance with iso 8528-1, iso-3046-1, bs 5514, as 2789 and din 6271. // deration factor: altitude: c onsult your local m tu onsite energy distributor for altitude derations. temperature: c onsult your local m tu onsite energy distributor for temperature derations.
|