skkd 101/16 ? by semikron rev. 1 ? 23.12.2011 1 semipack ? 1 skkd rectifier diode modules skkd 101/16 features ? heat transfer through aluminium oxide ceramic isolated metal baseplate ? ul recognized, file no. e63532 typical applications* ? non-controllable rectifiers for ac/ac converters ? line rectifiers for transistorized ac motor controllers ? field supply for dc motors absolute maximum ratings symbol conditions values unit recitifier diode i fav sin. 180 t c =85c 134 a t c =100c 101 a i fsm 10 ms t j =25c 2500 a t j =130c 2000 a i 2 t 10 ms t j =25c 31250 a2s t j =130c 20000 a2s v rsm 1700 v v rrm 1600 v t j -40 ... 130 c module t stg -40 ... 125 c v isol a.c.; 50 hz; r.m.s. 1min 3000 v 1s 3600 v characteristics symbol conditions min. typ. max. unit diode v f t j =25c, i f = 300 a 1.45 1.60 v v (to) t j = 130 c 0.75 0.87 v r t t j = 130 c 2.20 2.45 m ? i rd t j = 130 c, v rrm 3ma r th(j-c) cont. per chip 0.19 k/w per module 0.095 k/w r th(j-c) sin. 180 per chip 0.2 k/w per module 0.1 k/w module r th(c-s) chip 0.22 k/w module 0.11 k/w m s to heatsink m5 4.25 5.75 nm m t to terminals m5 2.55 3.45 nm a 5 * 9,81 m/s2 w75g
skkd 101/16 2 rev. 1 ? 23.12.2011 ? by semikron fig. 11l: power dissipation per diode vs. forward current fig. 11r: power dissipation per diode vs. ambient temperature fig. 12l: power dissipation of two modules vs. direct current fig. 12r: power dissipation of two modules vs. case temperature fig. 13l: power dissipation of three modules vs. direct current fig. 13r: power dissipation of three modules vs. case temperature
skkd 101/16 ? by semikron rev. 1 ? 23.12.2011 3 fig. 14: transient thermal impedance vs. time fig. 15: forward characteristics fig. 16: surge overload current vs. time
skkd 101/16 4 rev. 1 ? 23.12.2011 ? by semikron this is an electrostatic discharge sensitive device (esds), international standard iec 60747-1, chapter ix * the specifications of our components may no t be considered as an assurance of component characteristics. components have to b e tested for the respective application. adjustments may be necessary. the use of semikron produc ts in life support appliances and syste ms is subject to prior specification and written approval by semikron. we therefore strongly recommend prior consultation of our staf f. skkd semipack 1
|