ac impellers tel: 425-222-5900 800-453-4569 www.mechatronics.com e-mail: sales@mechatronics.com fax: 425-222-5155 cooling simplified 0 100 200 air flow (cfm) static pressure - in. of water 300 400 500 600 0.25 0.50 0.75 1.00 1.25 1.50 1.75 1 2 1 = 60 hz 2 = 50 hz uf220apa series 2.79 0.02 (71 0.5) air ou t air ou t air in air in 0.1 (2) ?8.78 0.02 (?223 0.5) 0 5 . 6 ? 2 0 . 0 5 6 1 ? ( ) 5 . 0 2.52 0.01 (64 0.3) o 5 4 o 5 4 5-m4x0.7 0 . 4 1 0 5 . 0 0 6 3 ( ) 0 . 0 1 ? 8 2 . 2 ( 8 5 ? ) (223 dia. x 71 mm) 8.78 dia. x 2.79 inches features: backward curved impeller operating voltage: 115 or 230 vac operating temp. -40 ~ 50c construction: aluminum die cast motor base; ul94v-0 reinforced nylon impeller bearing option: ball bearing motor: permanent split capacitor required capacitor included air flow: centrifugal connection: 22 awg lead wires protection: thermal model no. rated voltage v freq. hz input power w rated cur. a locked cur. a speed rpm air volume max. static pressure (h 2 0) sound noise dba weight kg m3/min. cfm mm inch UF220APA12-H2C2A 115 50 90 0.63 0.88 2,500 14 500 35 1.4 65 1.5 115 60 117 0.80 0.93 2,650 15 530 38 1.7 70 1.5 uf220apa23-h2c2a 230 50 90 0.35 0.47 2,500 14 500 35 1.4 65 1.5 230 60 117 0.39 0.49 2,650 15 530 38 1.7 70 1.5 12.16.14
|