  subject to alterations and errors release 11/05 dimensions tr2 32mm 16mm 5mm 35mm tr3 32mm 26mm 5mm 35mm design a - type tr2 design b - type tr3 accessories - monitoring relays powermodules - tr series 1. functions plug-in power modul for transforming the supply voltage at terminals a1-a2 of tele monitorling relays series gamma and trend to internal operating voltage 24v~. 2. mechanical design sealed self-extinguishing plastic housing. ip-rating ip40 (if mounted) 3. electrical data and types nominal voltage type rated consumption rated load design 12vac tr2 - 12vac 2va 0.5va a tr3 - 12vac 4va 1.5va b 24vac tr2 - 24vac 2va 0.5va a tr3 - 24vac 4va 1.5va b 42vac tr2 - 42vac 2va 0.5va a tr3 - 42vac 4va 1.5va b 48vac tr2 - 48vac 2va 0.5va a tr3 - 48vac 4va 1.5va b 110vac tr2 - 110vac 2va 0.5va a tr3 - 110vac 4va 1.5va b 127vac tr2 - 127vac 2va 0.5va a tr3 - 127vac 4va 1.5va b 230vac tr2 - 230vac 2va 0.5va a tr3 - 230vac 4va 1.5va b 400vac tr2 - 400vac 2va 0.5va a tr3 - 400vac 4va 1.5va b 415vac tr3 - 415vac 4va 1.5va b 440vac tr3 - 440vac 4va 1.5va b 500vac* tr3 - 500vac 4va 1.5va b * only types g4pm! 4. ambient conditions ambient temperature: -25 to +55c storage temperature: -25 to +70c transport temperature: -25 to +70c relative humidity: 15% to 85% 5. mounting for mounting the module first the protective cup has to be removed. the module than can be concisely plugged into the mounting whole of the tele monitoring relay series gamma or trend. technical data 1.04-1
subject to alterations and errors accessories - monitoring relays probes - sk series 1. functions probe for monitoring level of conductive liquids. 2. mechanical design stainless steel probe, pvc covered, ip rating ip44 3. electrical data measuring voltage: max. 24vac 4. ambient conditions ambient temperature: sk1 0 to +60c sk2 and sk3 0 to +90c storage temperature: -25 to +90c transport temperature: -25 to +90c relative humidity: 15% to 85% 5. mounting type sk1: the sk1 is designed for being duck completely under water. it is fixed at the cable end and fixed at the depending level. type sk2 and sk3: the sk2 and sk3 can be mounted on a mounting plate or directly into the top cover of the tank. the connection box has to be installed in a way that it is never covered by liquids. dimensions technical data 21mm ca.140mm 16mm dimension a - typ sk1 12 radius r1" 5mm 20mm 55mm 75mm 40mm dimension b - typ sk2 13 radius r1" 5mm 20mm 55mm 75mm 40mm 2 dimension b - typ sk3 mounting example sk1 6. probe types 2 probes (sk2) 3 probes (sk3) length 500mm sk2 - 500 sk3 - 500 length 1000mm sk2 - 1000 a.a. sk3 - 1000 other dimensions on request
subject to alterations and errors accessories - monitoring relays base load component gle 1. functions base load element for tele mains decoupler. the base load element is connected in parallel to electronic loads to ensure that the mains decoupler can detect the switching on of the depending circuit. after the decoupler has reconnected the circuit to the supplying power network, the base load element warms up and changes from low-impendance to high-impedance (ptc-resistor). 2. mechanical design silicone covered ptc-resistor with connection wires for built-in applications. 3. elektrische daten and ger?tetypen ptc-resistor resistance (20c): approx. 3.7k ? resistance (nominal temperature): approx. 12k ? nominal temperature at 230vac: approx. 70c (20c ambient temperature): 4. ambient conditions ambient temperature: -25 to +55c storage temperature: -25 to +70c transport temperature: -25 to +70c relative humidity: 15% to 85% 5. mounting the base load element has to be connected in parallel to the load . connections l1 n pe mains decoupler onf3, cnf3 gle technical data mounting plate mp 1. functions mounting plate for fixing tele devices on a mounting plate or wall. 2. mechanical design self-extinguishing plastic, three drillholes diameter 4mm. technical data
subject to alterations and errors www.tele-power-net.com accessories - monitoring relays front cover for gamma series 1. functions sealable front cover for gamma monitoring relays 2. mechanical design plastic cover technical data