cui .com date 11/14/2012 page 1 of 6 series: etsa 60w-u description: ac-dc power supply model output voltage output current output power ripple and noise 1 ef ciency level (vdc) max (a) max (w) max (mvp-p) etsa120500u 12 5 60 200 v etsa190342u 19 3.42 60 240 v ETSA240270U 24 2.7 60 240 v notes: 1. at full load, 100 ~ 240 vac input, 20 mhz bandwidth oscilloscope, each output terminated with 10 f aluminum electrolytic and 0.1 f ceramic capacitors. features ? up to 60 w power ? universal input (90~264 vac) ? compact size ? single regulated output from 12~24 v ? over voltage and short circuit protections ? ul/cul, intertek and pse safety approvals ? level v efficiency ? custom designs available rohs pg ac -d c p o wer su ppl y part number key etsa120500u c - xx - sz - cxx dc plug type factory designation base number example of 12 vdc, 5 a reserved for custom con gurations input cable: c = included blank = no cable
cui .com date 11/14/2012 page 2 of 6 cui inc series: etsa 60w-u description: ac-dc power supply input parameter conditions/description min typ max units voltage 90 264 vac frequency 47 63 hz current 12 v output all other outputs 1.4 1.5 a a no load power consumption 12 v output all other outputs 0.3 0.5 w w output parameter conditions/description min typ max units line regulation 1 % load regulation 5 % protections parameter conditions/description over voltage protection output voltage clamped by internal protection zener short circuit protection output shut down, auto restart safety & compliance parameter conditions/description min typ max units isolation voltage input to output at 10 ma for 1 minute 1,500 vac insulation resistance input to output at 500 vdc 100 m safety approvals ul/cul (ul 60950-1), en 60950-1/iec 60950-1, pse emi/emc fcc part 15, subpart b, class b; ce; cispr 22, class b; ices-003; ansi c63.4; en 61204-3; en 55022; en 55024; en 61000-(2, 3); iec 61000-4-(2, 3, 4, 5, 6, 8, 11) leakage current 12 v output all other outputs 0.35 0.25 ma ma rohs compliant yes environmental parameter conditions/description min typ max units operating temperature 040c storage temperature -10 70 c operating humidity 20 80 % storage humidity 10 90 %
cui .com date 11/14/2012 page 3 of 6 cui inc series: etsa 60w-u description: ac-dc power supply mechanical drawing mechanical parameter conditions/description min typ max units dimensions 4.488 x 1.850 x 1.276 (114 x 47 x 32.4 mm) inch weight 1 230 g notes: 1. weight does not include ac cord units: mm
cui .com date 11/14/2012 page 4 of 6 cui inc series: etsa 60w-u description: ac-dc power supply cord length 9510 2.8~4.0mm 213 48b s&t ac cord pe 1830 +200 +30 ul svt 18awgx3c vw-1 yp-12/yc-12 130 +0 -30 21.4 max. 6.05 min. 17.75 max. 171 6.30.05 12.70.13 11.90.1 ?4.750.05 14.6 max. 10.8 min. 1.50.1000 5 +0.5 0 2.5 +0.5 0 40.1 140.2 model no. cable gauge cord length etsa120500u 16 awg 1,000 mm 100 etsa190342u 18 awg 1,530 mm 100 ETSA240270U 18 awg 1,530 mm 100 dc cord
cui .com date 11/14/2012 page 5 of 6 cui inc series: etsa 60w-u description: ac-dc power supply output plug options stripped and tinned *tip positive ?3.5 +0/-0.1 140.5 ?3.5 +0/-0.1 140.5 a c b a b c d c a b c c a b a b p1r p1 right angle pxr standard px right angle pxxr st stripped and tinned p xx x x standard pxx n = center negative plug polarity: ?blank? = n/a p = center positive plug angle: ?blank? = standard r = right angle plug type dc plug type eiaj plugs locking dc plug standard dc plug 3.5 mm phono plug 255 92 *contact cui for additional output plug options. a b c unit p5/p5r 5.5 2.1 9.5 mm p6/p6r 5.5 2.5 9.5 mm p7/p7r 3.5 1.35 9.5 mm p8/p8r 3.8 1.35 9.5 mm p9/p9r 3.8 1.05 9.5 mm a b c unit p10 5.5 2.1 9.5 mm p11 5.5 2.5 9.5 mm eiaj a b c d unit p12/p12r eiaj-1 2.35 0.7 9.5 na mm p13/p13r eiaj-2 4.0 1.7 9.5 5.0 mm p14/p14r eiaj-3 4.75 1.7 9.5 5.0 mm
date 11/14/2012 page 6 of 6 cui inc series: etsa 60w-u description: ac-dc power supply this device complies with part 15 of the fcc rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. cui offers a one (1) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to b e accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use . cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 12/05/2011 1.01 updated p7/p7r b dimension, v-in nity branding removed, safety and emi/emc data updated 08/15/2012 1.02 updated dc cord information 11/14/2012 the revision history provided is for informational purposes only and is believed to be accurate. revision history
|