smallest filtered power entry modules with metric fuseholders the gg series power entry modules combine the functions of a general purpose rfi filter with an iec power cord connector and single or dual metric fusing, in the smallest possible panel space. a choice of .250terminals or wire leads is available for the load-side terminations. for maximum cost effectiveness, 6 amp models should be used for all applications rated 6 amps or less, unless the higher performance of the 3 amp models, or the much higher performance of the 1 amp models, is needed. models with c-suffix additionally incorporate a ground choke 1 to isolate the equipment chassis from external ground at rf frequencies. hg series a medical version of our gg series, these filters offer the same compact design but reduce the line-to-ground capacitance in order to meet ul 2601 patient care requirements. for more information on ul2601 specification, see appendix c. note: when using the models with an iec connector, remember that the leakage current of the companion line cord, ga400, is more significant than that of the filter - which may disqualify this line cord from use in patient care applications. specifications maximum leakage current,each line-to-ground hg models gg models @ 120 vac 60 hz: 2 a .25 ma @ 250 vac 50 hz: 5 a .42 ma hipot rating (one minute): line-to-ground 1550 vac line-to-line 1450 vdc operating frequency: 50/60 hz rated voltage (max.): 250 vac fuse (not included): accepts one 5x20mm fuse (-1 models) or two 5 x 20 mm fuses (-2 models) minimum insertion loss in db: line-to-ground in 50 ohm circuit current frequency-mhz rating .01 .05 .10 .15 .5 1 5 10 30 gg/gs models 1a 12 23 29 32 41 47 50 50 55 3a C 10 15 19 30 36 48 50 53 6a C 1 4 10 16 22 36 40 50 hg models 1a 12 23 29 32 40 40 28 22 18 3a C 10 15 19 25 26 22 21 21 6a C 4 10 14 18 18 14 14 14 line-to-line in 50 ohm circuit current frequency-mhz rating .01 .15 .5 1 3 5 10 30 gg/gs models 1a 1 3 14 23 41 47 50 44 3a 1 2 11 14 25 38 44 40 6a 1 2 10 13 23 33 39 42 hg models 1a 1 3 26 35 35 35 27 20 3a 1 2 30 30 30 30 30 30 6a 1 2 30 30 30 30 30 30 112 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. gg/hg series gg series corcom product guide h g1/gg1 g g8 electrical schematics gg/gs/hg gg-c resistor location for reference only. note 1: depicts single fuse for -1 models. note 2: for hg delete line-to-ground capacitors. caution: do not attempt to operate a single-fused model without the fuse door in place! ul recognized csa certified vde approved line note 1 note 2 load line note 1 note 2 load
smallest filtered power entry modules with metric fuseholders (continued) case styles case dimensions abcde .015 part no. (max) (max) (max) (max) .38 egg1-1/egg1-2/ 2.15 1.13 1.29 1.417 1.76 ehg1-2 54.5 28.7 32.8 36.0 44.7 egg8-1/egg8-2 2.02 1.13 1.29 1.417 1.76 egg8c-1/egg8c-2 51.1 28.7 32.8 36.0 44.7 egs1-1/egs1-2 2.13 1.13 1.28 1.46* 1.42 ehgs1-2 54.0 28.7 32.5 36.0 36.1 egg1c-1-1/egg1c-2 2.45 1.13 1.28 1.46* 1.42 62.23 28.7 32.5 36.0 36.1 *max 113 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p o w e r e n t r y m o d u l e s gg/hg series corcom product guide gg1/hg1 gg8 egs recommended panel cutouts t ypical dimensions: terminals: .250 [ 6.35 ] (3) holes: .07 [ 1.8 ] dia. mounting holes: .126 [ 3.20 ] dia. (2) typical dimensions: wire leads: 5.0 [ 127.0 ] min. 18 awg mounting holes: .126 [ 3.20 ] dia. (2) part number 1 rfi filter type 2 current rating 3 metric fuseholders load side terminations 1egg1-1 general purpose 2 1 1 .250 [ 6.35 ] terminals (3) 1egg1-2 general purpose 1 2 .250 [ 6.35 ] terminals (3) 1egg8-1 general purpose 1 1 5.0 [ 127.0 ] wire leads 1egg8-2 general purpose 1 2 5.0 [ 127.0 ] wire leads 1egs1-1 general purpose 1 1 .250 [ 6.35 ] terminals (3) 1egs1-2 general purpose 1 2 .250 [ 6.35 ] terminals (3) 3egg1-1 general purpose 3 1 .250 [ 6.35 ] terminals (3) 3egg1-2 general purpose 3 2 .250 [ 6.35 ] terminals (3) 3egg8-1 general purpose 3 1 5.0 [ 127.0 ] wire leads 3egg8-2 general purpose 3 2 5.0 [ 127.0 ] wire leads 3egs1-1 general purpose 3 1 .250 [ 6.35 ] terminals (3) 3egs1-2 general purpose 3 2 .250 [ 6.35 ] terminals (3) 6EGG1-1 general purpose 6 1 .250 [ 6.35 ] terminals (3) 6egg1-2 general purpose 6 2 .250 [ 6.35 ] terminals (3) 6egg8-1 general purpose 6 1 5.0 [ 127.0 ] wire leads 6egg8-2 general purpose 6 2 5.0 [ 127.0 ] wire leads 6egs1-1 general purpose 6 1 .250 [ 6.35 ] terminals (3) 6egs1-2 general purpose 6 2 .250 [ 6.35 ] terminals (3) 1ehg1-2 medical 1 2 .250 [ 6.35 ] terminals (3) 3ehg1-2 medical 3 2 .250 [ 6.35 ] terminals (3) 6ehg1-2 medical 6 2 .250 [ 6.35 ] terminals (3) 1ehgs1-2 medical 1 2 .250 [ 6.35 ] terminals (3) 3ehgs1-2 medical 3 2 .250 [ 6.35 ] terminals (3) 6ehgs1-2 medical 6 2 .250 [ 6.35 ] terminals (3) 1 ground choke available on general purpose models. add suffix "c" (1egg1 c -1). does not include egs models. 2 general purpose filter for susceptibility applications. 3 current rating @120 vac and 250 vac. for panel thickness . 032-.080 [ . 81-2.03 ] radius: 0.138 [ 0.35 ] a d e c b b c a d e blue green/yellow brown d e a b c .6 15.2 1 .14 29.0 1.417 3 6.0 1.30 33.0 gg / hg front or back mount gs / hgs front mount only 1.24 31.5 1.29 32.8
|