KK-1328-40 usa jmk inc 15 caldwell dr. amherst, nh 03031 ph: 603 886-4100 fx: 603 886-4115 email: info@jmkfilters.com eur jmk inc glasgow g13 1dn scotland uk ph: 44-(0) 7785310729 fax: 44-(0) 141 589 1884 operating voltage = ____________________0 to 63vdc operating current = ______________________ 40 amp operating temperature = 40 amp = _____________________ (-20 - 50oc) 37 amp = _____________________ (-20 - 55oc) 35 amp = _____________________ (-20 - 60oc) 30 amp = _____________________ (-20 - 67oc) 27 amp = _____________________ (-20 - 72oc) storage temperature = _______________-40oc - 100oc diel. withstanding (l-case) = _____________ 1000 vdc diel. withstanding (l-l) = ________________ 1000 vdc max residual volt after 1 sec = _____________34 volts weight = _________________________________1.9 lb max torque on terminals = _________________25 in.lb calculated mtbf = _____________7,386,888 hrs @ 30c gb failure rate = _______________________________0.135375 this filter delivers high common mode and differential mode insertion loss for dc power systems. the filter can be used for either commercial applications or for applications involvin g mil-std-461d, e, or f. if the older mil-std? 461c is required, the circuit can be re-arranged to accommodate the ?c? version. if severe shock and vibration is a requirement, contact our engineering department to discuss any possible mechanical modifications. insertion loss vs. frequency
|