dps - 40ap - 10 a input voltage range 90~264vac auto range frequency 47~63hz efficiency the average efficiency at 25%, 50%, 75% and 100% load 87% input current 90~132vac /12v/3.33a load 1.2a 180~264vac / 12v/3.33a load 0.6a output 12v 0a to 3.33a protection over - current auto recovery over - temperature latch short auto recovery over - voltage auto recovery environment operating temp. 0 to 50 c full load ,60 c 80% load, 70 c 60% load storage temp. - 20 to 70 operating humidity 10 % - 9 0% storage humidity 10 % - 9 5% features ? total power 40w ? 90- 264vac auto range input ? high reliability: 100,000 hours @ full load and normal input (25 ) ? protection: short / over - current / over - voltage / over - temperature ? ccc : 5000 meter ? bulk cap: jp type ? safety: ul/cul, tuv, cb by demko ,ccc ? emi: class b 50(w) x 28(h) x 95(l) mm
dps - 40ap - 10 a safety standards/directives electrical safety ul/cul, tuv, cb,ccc,ce, bsmi refer to en 60950 - 1 ce in conformance with emc directive 2004/108/ec and low voltage directive 2006/95/ec emc emi: refer to cispr 22 ,fcc ,vcci:class b esd(iec61000 - 4 - 2) air discharge: 8kv min contact discharge: 4 kv min. eft(iec61000 - 4 - 4) +/ - 2kv surge(iec61000 - 4 - 5) common mode:+/ - 4kv different mode:+/ - 2kv isolation input to output 3.0kvac
power de - rating curve
|