technical d at asheet adp series power adapters 19v 40w/65w/90w www. deltapsu .com ( january 201 6 , rev. 1.0 ) 1 adp 19v highligh ts & features energy star compliance (level vi ) it safety approvals 100k hours mtbf over - voltage/load/temperature & short circuit protections low leakage current safety standards cb certified for worldwide use model information adp series power adapters model number input v oltage range output v oltage output cur r ent adp - 40kd bbbm 90 - 264vac 19vdc 2.1a adp - 65jh hban 90 - 264vac 19vdc 3.42a adp - 90md hdm 90 - 264vac 19vdc 4.74a specifications input ratings / characteristics a
p - 4-k
bbbm a
p - 65jh hban a
p - 9-m
h
m nominal input voltage 100 - 240vac input voltage range 90 - 264vac nominal input frequency 50 - 60hz input frequency rang 47 - 63hz input current 1.2 a max at 100vac input voltage 1.5a max at 100vac input voltage inrush current limit (cold start) no damage efficiency at nominal input voltage 85% 84% active mode efficiency @ 115vac >88% active mode efficiency @ 230vac >85.30% >87% >88% no load power consumption <0.1w @ 115vac/60hz , <0.3w @ 230vac/50hz <0.21w @ 115vac/60hz leakage current <100ua at 240vac/50hz <50ua at 240vac/50hz <75ua at 240vac/50hz
technical d at asheet adp series power adapters 19v 40w/65w/90w www. deltapsu .com ( january 201 6 , rev. 1.0 ) 2 output ratings / characteristics a
p - 4-k
bbbm a
p - 65jh hban a
p - 9-m
h
m rated voltage 19v voltage range 18.05 ~ 19.95v current 2.1a 3.42a 4.74a output ripple and noise 350 mv pk - pk 300mv pk - pk 380mv pk - pk turn on delay time 5 seconds @ 100 - 240vac 2 seconds @ 100 - 240vac hold - up time the output voltage shall be sustained 5ms within regulation requirement after loss 100vac and maximum load. rise time dc output rise time from 10% to 90% of output voltage shall be less than 30ms at nominal line and maximum load dc output rise time from 10% to 90% of output voltage shall be less than 100ms at nominal line and maximum load transient load response 0.1a to 100% load at 2.5a/us slew rate and frequency is 10hz to 10khz 0% to 50% and 50% to 100% 1.0a/us slew rate and frequency is 100hz environment a
p - 4-k
bbbm a
p - 65jh hban a
p - 9-m
h
m operating temperature 0 ? to +40 ? shipping/storage temperature - 30 ? to +80 ? - 20 ? to +85 ? . operating humidity 8% to 90 % rh (non - condensing) shipping/storage humidity 5% to 95% rh (non - condensing) lightning surge immunity iec - 1000 - 4 - 5 level 3 requirements l - n 1kv/1.2 * 50us 5 times no damage iec - 61000 - 4 - 5 level 3 requirements l - n 1kv/1.2 * 50us 5 times no function error l - fg 2kv/1.2 * 50us 5 times no damage. electric fast transients (eft) iec - 1000 - 4 - 4/1995 en 61000 - 4 - 4 electrostatic discharge (esd) 15kv air discharge 8kv contact discharge dielectric withstand voltage (hi - pot) between ac input and secondary ac 3kv test time 1 minute; 100% of line products of this adapter shall be applied 3000vac for 2 seconds between ac input terminals and output terminals. cut off current 3ma. between ac input and secondary ac 3kv test time 1 minute; 100% of line products of this adapter shall be applied 3 000vac for 2 seconds between ac input terminals and output terminals. cut off current 10ma. 100% of line products of this adapter shall be applied 3000vac for 1 seconds between ac input terminals and output terminals. cut off current is 10ma. insulation resistance the insulation resistance shall be not less than 30m ohms after application of 500vdc/10ma for 1 minute. the insulation resistance shall be not less than 20m ohms after application of 500vdc/10ma for 1 minute electromagnetic interference (emi) (a) fcc class b (b) cispr 22 class b (c) vcci class b (a) fcc class b (b) cispr 22 class b (c) vcci class b (a) fcc class b (b) cispr 22 class b (c) vcci class b mtbf 150,000 hours 100,000 hours altitude 5,000m (16,400 ft)
technical d at asheet adp series power adapters 19v 40w/65w/90w www. deltapsu .com ( january 201 6 , rev. 1.0 ) 3 protections a
p - 4-k
bbbm a
p - 65jh hban a
p - 9-m
h
m over v oltage the output shall be protected to latch off at over - voltage condition, maximum value can t be over 29v. the output shall be protected to latch off at over - voltage condition , maximum value can t be over 27 v. the output shall be protected to latch off at over - voltage condition, maximum value shall be more than 22v and be less than 27v. overload / overcurrent the maximum constant current shall be more than 2.1a and be less than 5.0a at 90vac and 264vac. the adaptor shall be auto - recovery. the maximum constant current shall be more than 4.1a . the adapter shall be auto - recovery the minimum constant current shall be more than 5.214a. the maximum constant current shall be less than 6.636a. the output shall be prot ected to latch off at over - current condition. over temperature latch mode short circuit auto - recovery mechanical a
p - 4-k
bbbm a
p - 65jh hban a
p - 9-m
h
m color black outline dimensions (l x w x d) 89.5 * 37.0 * 26.5 mm 3.52 * 1.45 * 1.04 in 108.0 * 46.0 * 29.5 mm 4.25 * 1.81 * 1.16 in 127.0 * 51.0 * 30.5 mm 5.0 * 2.0 * 1.2 in ac inlet type socket c6 type dc cable type ul 1571 22awg ul1571 #awg18 #awg18 dc cable length 1800 mm dc connector - od 5.5 mm 5.5 mm 5.5 mm dc connector - id 2.5 mm 2.5 mm 1.7 mm dc connector - length 12.5 mm 11 mm 11 mm
technical d at asheet adp series power adapters 19v 40w/65w/90w www. deltapsu .com ( january 201 6 , rev. 1.0 ) 4 mechanical adp - 40kd bbm adp - 65jh hban
technical d at asheet adp series power adapters 19v 40w/65w/90w www. deltapsu .com ( january 201 6 , rev. 1.0 ) 5 adp - 90md hdm
|