  Datasheet File OCR Text:
  ld w 120 series are single or two phas e ac or dc input din rail switching power s upplies . its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes it market leader for various industrial telecom and renewable energy applications . ldw 120 series are class i isolation device s suita ble for selv and pelv circuitry and are designed to be mounted on din rail and installed inside a protective enclosure. ? high efficienc y ? single or two phase input ac 187 C 550 v ac ? wide dc input range 250 - 725 v dc ? c ompact size, only 40 mm width ? 150% overload capability ? rohs compliant ? industrial control ? communication ? instrumentation equipment ? renewable
2 ldw120 series tech.support@psbel.com ldw 120 - 12 200 - 500 v ac (250 - 72 5 vdc) 1 / 2 12 C 15 vdc 8 C 7 a ldw120 - 24 200 - 500 v ac (250 - 72 5 vdc) 1 / 2 24 vdc 5 a ldw120 - 48p 200 - 50 0 vac (250 - 725 vdc ) 1 / 2 48 vdc 2.5 a i ncludes i nternal oring diode spec ifications are measured at 25c, and 400 vac / 50 hz , typical unless otherwise stated. input ac voltage range rated , single or two phase , ul certified operating 200 C 500 vac 187 - 550 vac input dc voltage range rated, ul certified 250 C 725 vdc (300 C 500 vdc) input frequency range 47 - 63 hz input ac current vin = 200 vac vin = 500 vac 1.4 a 0.7 a input dc current vin = 250 vac vin = 725 vac 0.8 a 0.3 a inrush peak current < 40 a internal protection fuse none, external fuse must be provided external protection on ac line it is strongly recommended to provide external surge arresters (spd) according to local regulations. mcb 6 a c curve or 6 a d curve output power 120 w rated voltage (voltage adjustment range) ldw120 - 12 ldw120 - 24 ldw120 - 48p 12 C 15 vdc (12 C 15 vdc) 24 vdc (23 C 28 vdc) 48 vdc (45 C 55 vdc) continuous current (uout nom) ldw120 - 12 ldw120 - 24 ldw120 - 48p 8 - 7 a 5 a 2.5 a overload limit ldw120 - 12 ldw120 - 24 ldw120 - 48p > 10 a / 30 s > 7.5 a / 30 s > 3.75 a / 30 s short circuit peak current ldw120 - 12 ldw120 - 24 / ldw120 - 48p > 20 a / 3 00 ms > 14 a / 3 00 ms load regulation 1% ripple & noise 11 0 mvpp hold up time vin = 2 4 0 vac vin = 4 00 vac 17 ms 60 ms efficiency ldw120 - 12 ldw120 - 24 ldw120 - 48p > 81% > 8 8 % > 8 6 % dissipated power ldw120 - 12 ldw120 - 24 ldw120 - 48p < 2 5 w < 1 7 w < 19.5 w output over voltage protection ldw120 - 12 ldw120 - 24 ldw120 - 48p > 18 vdc > 33 vdc > 68 vdc
ldw120 series 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2016 bel power solutions & protection bcd.00719_ aa parallel connection (p) models include internal oring circuit protections hiccup at the overload limit with auto reset over temperature overvoltage status signals green led = dc ok red led = overload dry contact (1 a / 30 v) note: power rating, losses, efficiency, ripple, thermal behaviour may change outside of the nominal rated input range. operating temperature ul certified up to 45c (start - up type tested: - 40 c ) 1 - 40 to + 70c storage temperature - 40 oc - + 80oc derating - 1.2 w / c over 60 c humidity non - condensing 5 - 95% rh life time expectancy a t 25 c ambient , full l oad 84914 h (9.6 years) overvoltage category pollution degree iii 2 (iec 664 - 1) isolation voltage input to output input to ground output to ground 4.2 kvdc 2.2 kvdc 0.75 kvdc safety standards & approvals ul508 (certified) ul60950 (certified for ld w120 - 24 model) en60950 (reference) emc standards emission en55022:2010 (cispr22) en55011:2009/a1:2010 class a class a immunity en61000 - 4 - 2:2008 en61000 - 4 - 3:2006 /a2:2010 en61000 - 4 - 4:2012 en61000 - 4 - 5:2014 en61000 - 4 - 11:2004 /a1:2010 level 3 level 3 level 3 level 4 level 2 protection degree en60529:1989 / a:2013 ip20 vibration s inusoidal iec 60068 - 2 - 6:2007 (5 - 17.8 hz: 1.6 mm; 17.8 - 500 hz: 2g 2hours / axis (x, y, z) shock iec 60068 - 2 - 27:2008 (30 g 6 ms, 20 g 11 ms; 3 bumps / direction, 18 bumps total) 1 possible with load derating. weight 500 g dimensions (w x h x d) 40 x 115 x 110 mm mounting rail iec 60715/h15/th35 - 7.5( - 15) connection terminals screw type pluggable (24 - 12 awg) 2.5 mm2 case material aluminum
4 ldw120 series tech.support@psbel.com figure 1 . mechanical dr awing 1 ac/dc input 2 dc output (load) 3 diagnostic output (dry contact, nc output ok) 4 green led: output ok 5 red led: overload 6 output voltage adjustment input connection o utput connection single phase: l = line n = neutral = earth ground + = positive dc - = negative dc dry contact = nc two phase: l1 = phase 1 l2 = phase 2 = e arth ground dc: l1(n) = - negative dc l2(l) = + positive dc = e arth ground nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appeara nce of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of LDW120-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X