? 2015 bel power solutions, inc. north america +1.866.513.2839 asia - pacific +86.755.29885888 europe, middle east +353 61 225 977 tech.support@psbel.com belpowersolutions.com bcd.00293 _a e ? very high efficiency up to 93% ? input voltage range: 400 - 800 vdc ? up to 4 kw power ? full galvanic isolation between input and output ? can bus serial interface ? e - mark e12*10r00 - 10r05*13669 ? adjustable output voltage ? over temperature, output overvoltage and overcurrent protection, input and output reverse polarity protection ? liquid or convection cooled models available ? protection degree ip65 and ip67 the bel power solutions 700dnc40 - 12 - xg is a 4 kw dc/dc converter that creates dc voltages in hybrid and electric vehicles necessary to power low voltage accessories. liquid or convection cooled dc/dc converter operates at input voltages from 400 to 800 vdc a nd power range up to 4000 w/ 3300 w ( li quid/convection cooled model ).
700dnc40 - 12 - xg ? 2015 bel power solutions, i nc. +353 61 225 977 tech.support@psbel.com belpowersolutions.com bcd.00293_a e model description 700dnc40 - 12 - 8 g liquid c ooled model 700dnc40 - 12 - c g convection cooled model 700dnc40 - con - kit - 8g mating connectors kit C signal connector housing and pins, hv connector assembled with 3 m cable 700dnc40 - con - kit - 9g mating connectors kit - housing and pins parameter description / condition min nom max unit input voltage 400 700 800 vdc input current 11 adc efficiency @ vin = 700 vdc, vo = 14.4 v, io nom = 229 a 92 % input line interruption converter shutdown 390 vdc input capacitance 35 f inrush c urrent external pre - charging circuit required parameter description / condition min nom max unit output voltage vo to be trimmed via can bus, 10 bit resolution 9 14.4 16 vdc output current @ 14.4 vdc liquid cooled model convection cooled model 278 229 adc output power liquid cooled model convection cooled model 4000 3300 w line regulation vinmin - vinmax, @ 139 a, t _ coolant = 70c - 0.1 + 0.1 vdc output voltage set point @ 139 a, t _ coolant = 25c 14.35 14.4 14.45 vdc thermal drift - 0.05 +0.05 %/c periodic and random deviation @ 14.4 vdc / nominal load (differential mode 20 mhz) can high / low (differential mode 20 mhz) 280 * 3 00 * mvp - p transient response load step 1: 10 to 50 % and back load step 2: 50 to 100 % and back voltage over/under shoot: response time within 1 % of voset: - 1000 +1000 1000 mv s turn - on overshoot vonom, <100 ms 5 % redundant parallel operation up to 4 converters operating in parallel 16 kw remote sense cable drop (v) @ maximum load 0.5 v turn - on delay rise time (cext = 0 f) power - on - delay (from applying dc input voltage to vo = 90 %) power - on - time from ps_wake up (from ps_wake up on to vo = 90% of nom) 200 1 3 ms s s turn - off timing ps_wakeup delay; (monotonic vo fall) 0 100 ms capacitive load @ 14.4 vdc 0 10000 f * with external capacitors 47uf (electrolytic cap) & 1uf (x7r ceramic cap) connected to measuring point .
700dnc40 - 12 - xg ? 2015 bel power solutions, i nc. +353 61 225 977 tech.support@psbel.com belpowersolutions.com bcd.00293_a e parameter description / condition min nom max unit output over - current protection constant current liquid cooled model convection cooled model 285 235 a output over - voltage protection latch type, max. ov duration 1 ms 17 18 v output under - voltage protection max. uv duration 1 s, than hiccup 6 8 v over - temperature protection converter shutdown liquid cooled model convection cooled model 80 50 c input and output reverse polarity protection protective elements connected in series input fuse protection dc input: internal primary fuse, safety approved 20 a input low line protection turn on threshold turn off threshold 390 370 400 380 410 390 vdc input overvoltage protection recovery: vin re - cycling or ps_wakeup 810 850 v parameter description / condition can bus sae j1939 250 kbit/s or 500 kbit/s available remote sense signals sense positive (+12 v sense) sense negative ( - 12 v sense) 0.5 v compensation address bits internally pulled up to logic high (3.3v 100kohm) adr. 0 adr. 1 ps_wakeup logic input signal lv bat voltage hvil function hvil pin shorted internally part of hv connector can_speed can speed selection internally pulled up to logic high (3.3v 100kohm) logic low C 250kbit/s logic high C 500kbit/s parameter description / condition criterion safety certification report number: e12*10r00 - 10r05*13669 e - mark insulation basic: 3000 vdc basic: 3000 vdc input - to - protective earth input - to - output radiated emission un ece r10 4th edition esa level electrostatic discharge iec 61000 - 4 - 2 performance criterion b radiated electromagnetic field iec 61000 - 4 - 3 (10 v/m), sae j1113/21(100v/m) performance criterion b class b electrical fast transient iec 61000 - 4 - 4, level 2 (+/ - 2 kv, 2.5 khz) iso 7637 - 2; iso 7637 - 3, iso 16750 - 2 performance criterion b rf conducted immunity level 3 (10 v, 0.1580 mhz, am 80%, 1khz) performance criterion a rf disturbances immunity sae j1113 - 41 iso11452 - 4 (1 - 400 mhz, 60 ma) class a class b parameter description / condition min nom max unit altitude operating: 62 kpa absolute pressure non - operating:18.6 kpa absolute pressure 3600 12200 m operating temperature liquid cooled model : t_coolant with no derating t_amb @ full load, no power derating - 40 - 40 +70 +85 c convection cooled model : t_amb with no power derating - 40 +45 storage temperature - 40 + 9 5 c humidity sae j1455 shock sae j1455 vibration sae j1455, mil - std - 202g
700dnc40 - 12 - xg ? 2015 bel power solutions, i nc. +353 61 225 977 tech.support@psbel.com belpowersolutions.com bcd.00293_a e parameter description / condition manufacturer mpn input connector (in) high voltage connecter with hvil function tyco 2141272 - 1; key a output connector (out) male dual terminal thread m8 can bus and signal interface (ctrl) panel mounted tyco 776276 - 1 parameter description / condition maximum inlet coolant temperature +70c coolant medium/mixture 50/50 propylene or ethylene glycol/water min coolant flow 0.0208l/s (0.33gpm) max. coolant pressure 20psi max. pressure drop 1psi signal connector pin description signal connector output connector input connector pin signal description 1 ps_wakeup 2 adr0 3 adr1 4 can_speed 5 can_h 6 can_l 7 +sense 8 - sense parameter liquid cooled model convection cooled model dimensions (w x h x d) 270 x 113.3 x 343 mm 350 x 187.7 x 343 mm weight 11 kg 22 kg enclosure ip65 and ip67
700dnc40 - 12 - xg ? 2015 bel power solutions, i nc. +353 61 225 977 tech.support@psbel.com belpowersolutions.com bcd.00293_a e mechanical drawings - liquid cooled model 1 0 3 . 3 2 343 2 . 2 7 0 2 262 0.5 2 3 4 0 . 5 o 9 4 x tyco p/n 776276-1 gore vent tyco p/n 2141272-1 m8x16mm dpt. max. torque 20nm 2x male stud connector thread 1-14uns with o-ring 50 0.5 1 8 0 . 5 33 o 1 0 3 0 4x elastomer dampers
700dnc40 - 12 - xg ? 2015 bel power solutions, i nc. +353 61 225 977 tech.support@psbel.com belpowersolutions.com bcd.00293_a e mechanical drawings - convection cooled model nuclear and medical applications - products are not designed or intended for use as cr itical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice. 350 2 . 343 2 1 8 7 . 7 2 . 330 1 1 6 0 1 o 8 . 5 4 x
|