EF-1277-6D usa jmk inc 15 caldwell dr. amherst, nh 03031 p h: 603 886-4100 fx: 603 886-4115 email: info@jmkfilters.com eur jmk inc glasgow g13 1dn scotland uk ph: 44-(0) 7785310729 fax: 44-(0) 141 589 1884 operating voltage: ____________________ 85 to 250 v operating current: _______________________6.0 amp operating frequency: ____________________50/60 hz operating temperature: ________________ -20 to 50c diel. withstanding (line - case): ____________1500 vac diel. withstanding (line - line): _____________1500 vdc leakage current: __________1.0 ma @ 220 vac; 50 hz max residual voltage after 1 sec: ___________ 34 vo lts calculated mtbf: _________2,430,895 hrs @ 30c gb this filter was designed for use with the vicor ham m odule a nd als o pr o v id es the s am e f r equenc y attenuation as the hh-1055-6.3 there is an additional mov across the input to the filter in order to provide the recommended transient prote ction for the ham module. t his pack aging pr ovides another option for the mechanical designer and frees space on the board. other options are also available and our engineerin g department is always willing to help with design modifications. order p/n: EF-1277-6D insertion loss vs. frequency line load brown blue g / y
|